INSTALLATION
LOCATING GRILL/BUILT-IN CLEARANCES
Clearances to Non-Combustible Construction*:
A minimum of 3" clearance from the back of the grill to non-combustible construction is required for the purpose
of allowing the lid to open fully. It is desirable to allow at least 6" rear and side clearance to non-combustible
construction above the cooking surface for counter space. If you'll be using the rotisserie option, the space is es-
sential for motor and skewer clearance. The grill can be placed directly adjacent to non-combustible construction
below the cooking surface. (Fig. 03)
Clearances to Non-Combustible Construction*
3"
(7,6 cm)
WARNING!
Failure to maintain required clearances creates a fire hazard that may result in property damage or serious personal
18" / 45,7cm min.
injury.
WARNING!
The BH1 Grill is designed to function in an open area. Recommended minimum clearances should be maintained
to all surfaces (combustible and noncombustible) for optimum performance. Noncombustible material within the
minimum clearance area could result in discoloration or deterioration.
WARNING!
If a noncombustible material such as stucco is covering a combustible material such as wood, the minimum clear-
ance distance needs to be held to the wood. The presence of a noncombustible material inside the clearance zone
does not eliminate the minimum clearance zone to combustible material.
* DEFINITION OF NONCOMBUSTIBLE MATERIAL - Material which is not capable of being ignited and burned, such as
materials consisting entirely of, or a combination of, steel, iron, brick tile, concrete, slate, and plaster.
Clearances to Combustible Construction**:
Minimum of 18" (45,7cm) from the sides and rear of grill must be maintained to adjacent vertical combustible
construction, above the counter top level. You should take in account that there is a large volume of heat, and
smoke will exhaust from the rear of the grill. This may discolor or damage unprotected areas (Fig. 04). Do not
install under unprotected combustible construction without using a fire safe ventilation system.
A 18" (45,7cm) minimum clearance must be maintained under the counter top to combustible construction. The
clearance can be modified by a use of an insulated jacket.
BH1- 48R/RGI = 53-1/4"/ 135.25cm
BH1- 48RS = 53-7/16"/ 135,7cm
BH1- 36R/RGI = 41-5/8"/ 105,7cm
(with rotisserie motor mounted)
48" Models = 47-7/8"/ 121,6cm
36" Models = 35-7/8"/ 91,12cm
(without rotisserie motor mounted)
FIG. 03
26-5/8"/ 67.6cm
rotisserie
motor
24-1/4"
(61.6cm)
Bottom of
10-1/2"
support flange
(26,67cm)
2-3/16"
22-5/16"/ 56,7cm
/5,5cm
25-1/2"
(64,77cm)
18" / 45,7cm min.
rotisserie
motor
24-1/4"
/ 61,6cm
10-1/2"
/ 26,67cm
2-3/16"
/5,5cm
10
grill
exhaust
3" (7,6 cm) (to
non-combustible
construction /
minimum
lid clearance)
10 "
(25.4cm)
grill
exhaust
26-5/8"/ 67.6cm
18" / 45,7cm min.
(to combustible
construction)
Bottom of
support flange
10 "/ 25.4cm
22-5/16"/ 56,7cm
25-1/2"/ 64,77cm