Parameter
Description of parameter
code
Operation maintaining
time of the reverse-feed
074.FHT
stitching / presser foot
lifting solenoid
Upper stop position of
075.UEG
the needle
Degree between the
076.DRU
needle-down position
and needle-up position
Automatic retrieval of the
077.ANU
needle-up stop position
by turning the power ON
Degree between the
078. URU
origin and the needle-up
stop position
Initial
Explanation of the content represented by the
Range
value
In the case the reverse-feed stitching solenoid is
held in the ON state until the set time is reached,
the output power to the reverse-feed stitching
solenoid is turned OFF to protect the circuit. To
activate the solenoid again, manually press the
reverse feed stitching switch.
1 to 400
30s
In the case the presser foot lifting solenoid is held
in the operating state by slightly depressing the
back part of pedal, the output power to the presser
foot lifting solenoid is turned OFF to protect the
circuit. To activate the solenoid again, return the
pedal to its neutral position once, and slightly de-
press the back part of pedal again.
Fine adjustment of the upper stop position angle
of needle
Take "40" as zero point. When this value is de-
0 to 250
60
creased, the needle stops at a lower position.
When this value is increased, the needle stops at
a higher position.
The degree by which the sewing machine is
rotated in the reverse direction until the needle-up
1 to 360
165
position is reached can be set as desired while
using the needle-down stop position as the base
point.
ON: When the power to the sewing machine is
turned ON, the sewing machine automatically
retrieves the needle-up stop position and stops.
OFF/ON
ON
OFF: When the power to the sewing machine is
turned ON, the sewing machine does not automat-
ically retrieve the needle-up stop position.
The degree by which the sewing machine is
rotated in the reverse direction until the needle-up
0 to 360
0
position is reached can be set as desired while
using the origin as the base point.