Installation sequence
Electrical connections
P2 230 V parametrisable output:
DHW circulation pump or heating circuit pump for
heating circuit without mixer (in systems with low
loss header)
BCU burner control unit power supply (connected
A
in the delivered condition)
Power supply for accessories
B
Plug located externally on the right or left-hand
C
side of the appliance (see also following diagram)
Connections to extra low voltage (ELV) plugs

Outside temperature sensor

!
Terminals 1 and 2 on external plug
Cylinder temperature sensor (connected in the
%
delivered condition)

On-site connections on HMU heat management unit

Fig. 12
Plug located externally on the right or left-hand
C
side of the appliance (supplied separately)
Required plugs are supplied in separate packaging.
Outside temperature sensor
Fitting location for outside temperature sensor
North or north-westerly wall, 2 to 2.5 m above
ground level; in multi storey buildings, in the upper
half of the second floor
Not above windows, doors or vents
18
(cont.)
C
!
PlusBus
jF
Terminals 5 and 6 on external plug
CAN bus
lA
Information on connecting accessories
When connecting accessories observe the sep-
arate installation instructions provided with
them.
6 5 4 3 2 1
6 5 4 3 2 1
Provide strain relief for cables in the wiring chamber of
the HMU heat management unit using cable ties.
Not immediately below balconies or gutters
Never render over
Outside temperature sensor connection
2-core lead, length up to 35 m with a cross-section
2
of 1.5 mm
C
C