Viessmann VITODENS 222-F Installation And Service Instructions Manual page 88

Gas condensing storage combi boiler
Table of Contents

Advertisement

Troubleshooting
Fault messages
(cont.)
Fault number
System characteristics
on the display
F.543
Mixer closes. Heating circuit
pump is operational.
F.544
Mixer closes. Heating circuit
pump is operational.
F.545
Mixer closes. Heating circuit
pump is operational.
F.546
Mixer closes. Heating circuit
pump is operational.
F.547
Mixer closes. Heating circuit
pump is operational.
F.574
Control mode without room
influence
F.575
Control mode without room
influence
F.576
Control mode without room
influence
F.577
Control mode without room
influence
F.578
Control mode without room
influence
F.579
Control mode without room
influence
F.580
Control mode without room
influence
F.581
Control mode without room
influence
88
Cause
Short circuit, flow temper-
ature sensor for heating
circuit 1 with mixer
Lead break, flow tempera-
ture sensor, heating circuit
2 with mixer
Short circuit, flow temper-
ature sensor for heating
circuit 2 with mixer
Lead break, flow tempera-
ture sensor, heating circuit
3 with mixer
Short circuit, flow temper-
ature sensor for heating
circuit 3 with mixer
Room temperature sensor
for heating circuit 1 not
available
Lead break, room temper-
ature sensor, heating cir-
cuit 1
Short circuit, room tem-
perature sensor, heating
circuit 1
Room temperature sensor
for heating circuit 2 not
available
Lead break, room temper-
ature sensor, heating cir-
cuit 2
Short circuit, room tem-
perature sensor, heating
circuit 2
Room temperature sensor
for heating circuit 3 not
available
Lead break, room temper-
ature sensor, heating cir-
cuit 3
Measures
Check flow temperature sensor
TS1 on extension kit mixer (ADIO
electronics module). See
page 91.
Check flow temperature sensor
TS1 on extension kit mixer (ADIO
electronics module). See
page 91.
Check flow temperature sensor
TS1 on extension kit mixer (ADIO
electronics module). See
page 91.
Check flow temperature sensor
TS1 on extension kit mixer (ADIO
electronics module). See
page 91.
Check flow temperature sensor
TS1 on extension kit mixer (ADIO
electronics module). See
page 91.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.