Follow the instructions below to connect the machine to the electrical power supply system:
-
the pump must have an earth connection and must be protected against indirect contacts in
accordance with local regulations;
-
- if a differential switch is provided on the pump's electrical power supply as extra protection, the
switch must flip when it becomes aware of the presence of dispersions of current towards the earth
with a continuous component (constant pulsating current);
-
check that voltage is 1~230Vac, 50/60Hz.
The CPS comes with a Shuko EEC 7/7 type power plug.
Connect the plug in an accessible position in case it is necessary to deactivate the system.
In case of damage to the power cable, it must be replaced in an assistance centre or by qualified personnel.
The CPS comes with a 2 m shielded cable, for the pressure transducer, connected to the module. For
positioning see chapter 5.
x
Before switching on or after a long period without power, the display may flash; this
indicates the internal clock must be regulated (see chap. 5.3.1).
x
In particular situations, some other additional components (for ex. Filters, ext) might be
required to limit the electromagnetic interference