E08
Over voltage error
temporary
Over voltage error
E09
definitive
Absence of network
E10
power (in memory)
Power error
E11
Memory error
E12
Configuration error
E13
Undefined error
E99
Communication
485E
error
48
This error condition occurs when
the voltage exceeds by 10% the
nominal voltage (230V).
This alarm condition closes the J3
contact on the power board for
possible external signals (alarm
light, siren, etc.)
A definitive over voltage error
occurs after a temporary over-
voltage error is repeated 5 times.
This condition occurs following a
network absence.
This condition indicates a motor
power absorption error in terms of
its running status
This error occurs when eeprom is
unable to load the parameters
which have been entered.
This error occurs when the control
board
cannot
communicate with the power part.
This alarm condition closes the J3
contact on the power board for
possible external signals (alarm
light, siren, etc.)
This
error
occurs
unforeseen error takes place.
This signal refers to pump units
and is indicated when the devices
are not communicating correctly.
Page 21 of 30
21 - GB -
In this case, the module will
attempt
functioning after 1 minute and will
repeat the procedure up to five
times.
START/STOP or cut the power off
and wait until the LINE Led
switches off and after which
restart the system.
If the error occurs again, contact
customer care.
Press the START/STOP button or
cut off power and wait until the
red Led LINE goes off, then
power again to reset the system.
If the error occurs again, contact
your
nearest
centre.
Wait for a few minutes. If the
signal remains, press the button
START/STOP or cut the power off
and wait until the LINE Led
switches off and after which
restart the system.
Press the button START/STOP or
correctly
cut the power off and wait until the
LINE Led switches off and after
which restart the system.
If the error occurs again, contact
your nearest assistance centre.
when
an
Wait for a few minutes. If the
signal
remains,
nearest customer care centre.
x
Press
START/STOP or cut the
power off and wait until
the LINE Led switches off
and after which restart the
system.
x
Check the communication
cable.
If the error occurs again, contact
your
nearest
centre.
to
restart
normal
Press
the
button
customer
care
contact
your
the
button
customer
care

Advertisement