12.
Malfunctions
Direct intervention by the customer
In order to avoid unnecessary costs, ensure that the problem occurring in the machine is not included in the following table before calling the
servicing department.
DEFECT
The coffee machine does not function and
the indicator light (2) is off.
The coffee machine does not work but the
indicator light (2) is on.
The coffee machine does not heat up.
Leak from edge of filter-holder (21, 25).
Coffee flow time too short.
Water leaks from under the machine.
The coffee is warm and weak (after normal
time of brew and flow).
The reading on the pressure gauge (8) of the
pump pressure is greater than 9 bars.
CAUSE
No electricity.
Wrong programming of the switch-on times.
Wrong position of the switch (1a).
The undercup gasket is dirty with coffee resi-
due.
Coffee grinds too coarse.
Coffee too old.
Drainage tank clogged.
Air bubble in thermosyphonic circulation sys-
tem.
The pump’s by-pass valve is blocked.
REMEDY
Check that the electricity is on.
Check the position of the main switch (12).
Press the PROGR (32) key for a few sec-
onds to force switch-on.
Reprogram the clock (Paragraphs 3 and 4).
Press the switch knob (1a).
Clean with the supplied brush.
Grind the coffee more finely.
Change the coffee
Clean the tank.
Press the coffee distribution button 2/3 times
to try and eliminate the air bubble.
Call the authorized servicing department.