1
9
PHOTO044
A
PHOTO051
FOR MOMENTARY CONTACT TO CLOSE (B2 WIRING), PLEASE REFER TO INSTRUCTION BELOW
C2
C2 wiring: momentary contact to open
and stop, constant pressure to close
with 3 push button station. Activation
of safety device will reverse the door
during closing. Auxiliary devices to
function as an open/control and to
reverse the door during closing.
C2 to B2
Move red wire from #5 to #7
6
3 9
1
B2 wiring: momentary contact to
open, close and stop with 3 push
button station. Activation of safety
device will reverse the door during
closing. Auxiliary devices to function
as an open/close control and to
reverse the door during closing.
B2 to C2
Move red wire from #7 to #5
Move red wire from #7 to #5
37
Black & White
White
P
HOTO008
PHOTO038
B2
Black & White
White
Interface Module Jumper
Always set the jumper
Blue
1
located inside the
Interface Module on
Brown
9
N.O (Normally Open)
Orange
3
White
6
WARNING
Motorized doors can cause serious
injuries or death. Manaras strongly
recommends the use of entrapment
protection systems, especially in
the case of momentary contact to
close such as with B2 wiring or
timer to close.
WARNING
Wall control(s) must be located so
that the door is within sight of the
user.
If momentary contact (B2 mode) is
used, an external reversing device
must be install.
NOTE
(TK8200)