Maintenance
9.1 Inspection and maintenance
Manufacturer
Shell
FAG
Lubrication data
The following data is provided on the lubricant plate of the machine.
● Regreasing intervals in operating hours
● Regreasing amount in grams
● Grease type
Grease replacement intervals
The grease replacement intervals in these operating instructions or the regreasing intervals
indicated on the plate apply to the following conditions:
● Normal load
● Operation at speeds in accordance with rating plate
● Low-vibration operation
● Neutral ambient air
● High-quality rolling bearing greases
In the case of unfavorable operating conditions, reduce the relubrication intervals after prior
consultation with the manufacturer.
132
Grease type
Retinax LX2