Figure 18. Two subnet switch example (IPv4)
Table 3. Two subnet switch example
No.
Device
1
A0
2
A1
3
A2
4
A3
5
B0
6
B1
7
B2
8
B3
9
Switch A
10
Switch B
11
Host server 1, Port 0
12
Host server 1, Port 1
13
Host server 2, Port 0
14
Host server 2, Port 1
To enable CHAP, see the topic about configuring CHAP in the Dell EMC PowerVault ME4 Series Storage System Administrator's Guide.
SAS protocol
ME4 Series SAS models use 12 Gb/s host interface protocol and qualified cable options for host connection.
12Gb HD mini-SAS host ports
ME4 Series 12 Gb SAS controller enclosures support two controller modules. The 12 Gb/s SAS controller module provides four SFF-8644
HD mini-SAS host ports. These host ports support data rates up to 12 Gb/s. HD mini-SAS host ports are used for attachment to SAS
hosts directly. The host computer must support SAS and optionally, multipath I/O. Use a qualified cable option when connecting to a host.
24
Cable host servers to the storage system
IP Address
Subnet
192.68.10.200
10
192.68.11.210
11
192.68.10.220
10
192.68.11.230
11
192.68.10.205
10
192.68.11.215
11
192.68.10.225
10
192.68.11.235
11
N/A
N/A
N/A
N/A
192.68.10.20
10
192.68.11.20
11
192.68.10.21
10
192.68.11.21
11