Dell EMC FS25 Field Replacement Unit Manual
Dell EMC FS25 Field Replacement Unit Manual

Dell EMC FS25 Field Replacement Unit Manual

Ssd shelf guide
Table of Contents

Advertisement

Dell EMC FS25 SSD Shelf Guide
Version 7.0
Field Replacement Unit Guide
Rev 01
September 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FS25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dell EMC FS25

  • Page 1 Dell EMC FS25 SSD Shelf Guide Version 7.0 Field Replacement Unit Guide Rev 01 September 2019...
  • Page 2 MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED IN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE. Dell Technologies, Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Published in the USA.
  • Page 3: Table Of Contents

    Removing an LCC................40 Installing an LCC...................41 Transferring disks and disk filler modules..........42 Attaching an AC power cord................45 Verifying the status of the replacement DAE5S..........45 Connect the SAS cables..................47 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 4 Contents Installing the front bezel..................47 Closing the console................... 48 Verify the operation of the new disk drive............48 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 5: Figures

    Installing a disk filler module....................45 Attaching power cords......................45 LCC power LED........................ 46 LCC fault LED........................46 Power/cooling module fault LED..................46 Disk fault LED........................47 Bus (loop) ID LED......................47 Installing the bezel ......................48 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 6 Figures Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 7: Tables

    TABLES Document revision history....................11 Standard touch point colors....................17 Status lights........................32 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 8 Tables Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 9: Preface

    Preface Contact your Dell EMC technical support professional if a product does not function properly or does not function as described in this document. Note: This document was accurate at publication time. Go to the Dell EMC Online Support site, https://support.emc.com/, to ensure that you are using the latest version of this document.
  • Page 10 Ellipses indicate nonessential information that is omitted from the example Technical support To resolve issues with Dell EMC products, contact your contracted support provider or go to https://support.emc.com/. Your comments Your suggestions help us continue to improve the accuracy, organization, and overall quality of the user publications.
  • Page 11: Revision History

    Revision history Table 1 Document revision history Revision Date Description September 2019 Initial publication. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 12 Revision history Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 13: Fru Removal And Replacement

    CHAPTER 1 FRU Removal and Replacement The following topics are contained in this chapter: Common procedures ......................14 Disk replacement........................17 replacement........................21 Power/cooling module replacement..................25 Complete the procedure......................29 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 14: Common Procedures

    Note: These precautions are not a substitute for the use of an ESD kit. Follow them only in the event of an emergency. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 15: Hardware Acclimation Times

    Systems and components must not experience changes in temperature and humidity that are likely to cause condensation to form on or in that system or component. Do not exceed the shipping and storage temperature gradient of 45°F/hr (25°C/hr). Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 16: Removing, Installing, Or Storing Replaceable Units

    2. Unpack the part and place it on a static-free surface. 3. If the part is a replacement for a faulted part, save the packing material to return the faulted part. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 17: Standard Touch Point Colors

    If the console is covering the front of the to which you need access, open the console using the steps that follow. Refer to Figure 1 on page 18. Procedure 1. Grasp the right side of the console. 2. Pull the console to swing it open. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 18: Removing The Front Bezel

    2. Press the two latch buttons on the bezel surface to release the bezel from the cabinet. 3. Pull the bezel off the cabinet and put it on a clean, static-free surface. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 19: Removing A Disk

    30 seconds for the disk to stop spinning before pulling the disk completely out of the slot. If the disk’s fault LED light is off or mostly off, slowly pull the disk completely out of the slot. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 20: Installing A Disk

    5. Push the handle down to engage the latch. Figure 5 Installing a disk CL4720 6. Remove and store the ESD wristband. Installing the front bezel Procedure 1. Align the bezel with the enclosure. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 21: Closing The Console

    2. Gently push on the console until it is closed. LCC replacement This section describes how to replace an LCC. Removing a faulted LCC Before you begin Identify the faulted LCC by it amber fault LED. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 22: Lcc Fault Led

    Note where the cables connect to the LCC because you will reconnect them later. Figure 8 Disconnecting an LCC cable CL5983 3. Remove the LCC: Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 23: Removing An Lcc

    Press the orange handle buttons to release the LCC, pull the latches outward, and remove the LCC from its slot. Figure 9 Removing an LCC CL5984 4. Place the LCC on a clean, static-free surface. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 24: Installing A Replacement Lcc

    LCC is completely seated in the enclosure. Figure 10 Installing an LCC CL5985 4. Press the latches to secure the LCC. 5. Reconnect each cable to the port from which it was removed. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 25: Power/Cooling Module Replacement

    5 seconds before removing power from the second module. Procedure 1. Attach an ESD wristband to your wrist and the enclosure. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 26: Unplugging The Power Cord From An Ac Power Supply/Cooling Module

    Pull the latch outward and remove the power/cooling module from its slot. CAUTION To protect a running system from overheating, the enclosure will power down unless you replace the power cooling module within two minutes. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 27: Installing A Replacement Power/Cooling Module

    1. Install the power/cooling module in the enclosure within two minutes: a. Gently insert the power/cooling module into the enclosure, being sure that the module is completely seated. b. Press the latch in to secure the power/cooling module. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 28: Installing A Power/Cooling Module

    Plug the power cord into the power/cooling module. b. Secure the cord with the retention bail at the connector The bail prevents the power cord from pulling out of the connector. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 29: Complete The Procedure

    Complete the procedure Procedure 1. Return the failed or replaced part(s) to Dell EMC. Reuse the packaging from the new part(s) and use the included prepaid waybill for shipping. Reference the RMA number on the outside of the package.
  • Page 30 FRU Removal and Replacement Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 31: Replacing A 25-Slot Disk-Array Enclosure

    Verifying the status of the replacement DAE5S..............45 Connect the SAS cables......................47 Installing the front bezel......................47 Closing the console....................... 48 Verify the operation of the new disk drive................48 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 32: Identify The Failed Drive

    The drive slot/locations are marked on the chassis 0-24, but the DD OS software still references the slots as 1-25. It is important to identify the proper drive between the location called out in the FRU, and the location as specified in the software. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 33: Disconnect Cables

    Label each cable so you can easily identify where to reconnect. Figure 18 Disconnect LCC cables CL5983 2. On both power supplies, release the cable retention bail. 3. Disconnect both power cables. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 34: Opening The Console

    Refer to Figure 20 on page 34. Procedure 1. Grasp the right side of the console. 2. Pull the console to swing it open. Figure 20 Opening the console CL4699 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 35: Removing The Front Bezel

    à un relevage mécanique et/ou à l’aide d’une autre personne. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 36: Installing The Empty Replacement Dae5S On The Rails

    Installing the empty replacement DAE5S on the rails Procedure 1. With help from another person, lift the enclosure and, from the front of the cabinet/rack, slide the enclosure onto the rails. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 37: Sliding The Enclosure Onto The Rails

    2. Secure the front of the enclosure to the front vertical channels with four screws (two per side), but do not tighten the screws until they are all in place. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 38: Transferring Components From The Faulted Dae To The Replacement Dae

    DAE. Removing a power/cooling module Procedure 1. Press the orange handle button to release the module. 2. Pull the latch outward and remove the power/cooling module from its slot. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 39: Installing A Power/Cooling Module

    Installing a power/cooling module Procedure 1. Gently insert the power/cooling module into the enclosure, being sure that the module is completely seated. 2. Press the latch in to secure the power/cooling module. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 40: Removing An Lcc

    The LCC comes completely out of the DAE chassis. In addition to holding the latches, be prepared to support the LCC to avoid dropping it. Procedure 1. Locate the orange handle buttons on the LCC handles. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 41: Installing An Lcc

    2. Align the LCC with the enclosure opening and gently push the LCC straight into the enclosure, being sure the LCC is completely seated in the enclosure. 3. Press the latches to secure the LCC. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 42: Transferring Disks And Disk Filler Modules

    Installing disks out of their original order results in data unavailability, and possible data loss. Removing a disk About this task Refer to Figure 31 on page 43 while performing the procedure that follows. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 43: Removing A Disk

    4. Push on the orange latch tab until the disk is seated in the slot. 5. Push the handle down to engage the latch. 6. Remove and store the ESD wristband. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 44: Installing A Disk

    1. Insert your finger into the cutout on the bottom of the disk filler module. 2. With your thumb on the top of the disk filler module push the disk filler module into the slot until it clicks into place. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 45: Attaching An Ac Power Cord

    The retention bail prevents the power cord from pulling out of the connection. Figure 35 Attaching power cords Verifying the status of the replacement DAE5S Procedure 1. Verify that both LCC power LEDs are lit. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 46: Lcc Power Led

    LCC fault LED - one per LCC. Figure 37 LCC fault LED CL5982 Power/cooling module fault LED - one per module. Figure 38 Power/cooling module fault LED CL5987 Disk fault LED - one per disk. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 47: Connect The Sas Cables

    About this task Refer to Figure 41 on page 48 while performing the procedure that follows. Procedure 1. If present, remove the protective plastic strip from the front of the bezel. Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 48: Installing The Bezel

    This command checks that the drive is recognized. # disk show state Enclosure Disk 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 --------- ------------------------------------------------------------------------- --------- ------------------------------------------------------------------------- Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 49 3. After the rescan, if the output of the disk show state command displays any disks in the Unkown, Failed, or Absent states, run the disk unfail <enclosure-id>.<disk- command to unfail the disk. For example, to unfail enclosure 2, disk 2, type id> disk unfail 2.2 Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...
  • Page 50 Replacing a 25-Slot Disk-Array Enclosure Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide...