Dell EMC PowerVault ME4 Series Deployment Manual page 43

Hide thumbs Also See for PowerVault ME4 Series:
Table of Contents

Advertisement

1. Ensure that all network adapters have the latest supported firmware and drivers as described on Dell.com/support.
NOTE:
The Dell EMC PowerVault ME4 Series storage system supports only software iSCSI adapters.
2. Use the iSCSI cabling diagrams to connect the hosts to the storage system either by using switches or connecting the hosts directly
to the storage system.
3. Install MPIO on the iSCSI hosts:
a. Open Server Manager.
b. Click Manage > Add Roles and Features.
c. Click Next until you reach the Features page.
d. Select Multipath IO.
e. Click Next, click Install, and click Close.
f. Reboot the Windows server.
Assign IP addresses for each network adapter connecting to the iSCSI network
Perform the following steps to assign IP addresses for the network adapter that connects to the iSCSI network:
CAUTION:
IP addresses must match the subnets for each network. Make sure that you assign the correct IP addresses
to the NICs. Assigning IP addresses to the wrong ports can cause connectivity issues.
NOTE:
If using jumbo frames, they must be enabled and configured on all devices in the data path, adapter ports,
switches, and storage system.
1. From the Network and Sharing Center, click Change adapter settings.
2. Right-click on the network adapter, then select Properties.
3. Select Internet Protocol Version 4, then click Properties.
4. Select the Use the following IP address radio button and type the corresponding IP addresses recorded in the planning worksheet
described in the Prerequisites section (ex: 172.1.96.46).
5. Set the netmask .
6. Configure a gateway if appropriate.
7. Click OK and Close. The settings are applied to the selected adapter.
8. Repeat steps 1-7 for each of the required iSCSI interfaces (NIC 1 and NIC 2 in
port iSCSI
NICs).
9. From the command prompt, ping each of the controller IP addresses to verify host connectivity before proceeding. If ping is not
successful, verify connections and the appropriate IP/subnet agreement between interfaces.
Configure the iSCSI Initiator
Perform the following steps to configure the iSCSI Initiator on the host:
1. Open the Server Manager.
2. Select Tools > iSCSI Initiator. The iSCSI Initiator Properties dialog box opens.
If you are running the iSCSI initiator for the first time, click Yes when prompted to have it start automatically when the server reboots.
3. Click the Discovery tab, then click Discover Portal. The Discover Target Protocol dialog box opens.
4. Using the planning worksheet that you created in the Prerequisites section, type the IP address of a port on controller A that is on the
first subnet and click OK.
5. Repeat steps 3-4 to add the IP address of a port on the second subnet that is from controller B .
6. Click the Targets tab, select a discovered target, and click Connect.
7. Select the Enable multi-path check box and click Advanced. The Advanced Settings dialog box opens.
Select Microsoft iSCSI initiator from the Local adapter drop-down menu..
Select the IP address of NIC 1 from the Initiator IP drop-down menu.
Select the first IP listed in the same subnet from the Target portal IP drop-down menu.
Click OK twice to return to the iSCSI Initiator Properties dialog box.
8. Repeat steps 6-7 for the NIC to establish a connection to each port on the subnet.
NOTE:
Step 10 is required for multi-path configurations.
9. Repeat steps 3-8 for the NIC 2, connecting it to the targets on the second subnet.
NOTE:
After all connections are made, you can click the Favorite Targets tab to see each path. If you click Details,
you can view specific information the selected path.
10. Click the Configuration tab and record the initiator name in the Initiator Name field. The initiator name is needed to map volumes to
the host.
Table 6. Example worksheet for host server with dual
Perform host setup
43