Safety Guidelines; Safe Handling - Dell EMC PowerVault ME4 Series Deployment Manual

Hide thumbs Also See for PowerVault ME4 Series:
Table of Contents

Advertisement

Figure 2. Unpacking the 5U84 enclosure
1. Storage system enclosure
3. Documentation
5. Rackmount right rail (5U84)
DDICs ship in a separate container and must be installed into the enclosure drawers during product installation. For rackmount
installations, DDICs are installed after the enclosure is mounted in the rack. See
For enclosures configured with CNC controller modules, locate the SFP+ transceivers included with the shipment. See
transceiver for FC/iSCSI
CAUTION:
A 5U enclosure does not ship with DDICs installed, but the rear panel controller modules or IOMs are installed.
This partially populated enclosure is weights approximately 64 kg (142 lb). You need a minimum of two people to
remove the enclosure from the box.
When lifting the enclosure, verify that the straps are securely wrapped and buckled and position one person at
each side of the enclosure. Then, grip the straps securely by the loops and lift the enclosure out of the box by
using proper lifting techniques. Place the enclosure in an electrostatically protected area.

Safety guidelines

Always follow these safety guidelines to avoid injury and damage to ME4 Series components.
If you use this equipment in a manner that is not specified by Dell EMC, the protection that is provided by the equipment could be
impaired. For your safety and precaution, observe the rules that are described in the following sections:
Dell EMC PowerVault ME4 Series Storage System Getting Started Guide for product safety and
NOTE:
See the
regulatory information. Warranty information is included as a separate document.

Safe handling

Dell EMC recommends that only individuals with rack-mounting experience install an enclosure into a rack.
CAUTION:
Use this equipment in a manner specified by Dell EMC. Failure to do so may cancel the protection that is
provided by the equipment.
Unplug the enclosure before you move it or if you think that it has become damaged in any way.
A safe lifting height is 20U.
Always remove the power cooling modules (PCMs) to minimize weight before you move the enclosure.
Do not lift the enclosures by the handles on the PCMs—they are not designed to take the weight.
ports.
2. DDICs (Disk Drive in Carriers)
4. Rackmount left rail (5U84)
6. Drawers
Populating drawers with
DDICs.
SFP+
Before you begin
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault me4024

Table of Contents