Vallox 90 SE Series Instructions For Use And Maintenance Manual

Vallox 90 SE Series Instructions For Use And Maintenance Manual

Supply and extract air ventilation with heat recovery
Hide thumbs Also See for 90 SE Series:

Advertisement

SUPPLY AND EXTRACT AIR VENTILATION
WITH HEAT RECOVERY
MODELS:
VALLOX 90 SE R
VALLOX 90 SE L
DIGIT
SED
ELECTRONIC CONTROLLER
WITH LCD DISPLAY
Vallox
90
SE
• 1.09.332E
• 10.4.2009
• Code 3520
© VALLOX
CODE 3520
VTT certificate number
Direct current fan model
C326/05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 90 SE Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vallox 90 SE Series

  • Page 1 • 10.4.2009 • Code 3520 © VALLOX CODE 3520 VTT certificate number Direct current fan model C326/05 SUPPLY AND EXTRACT AIR VENTILATION WITH HEAT RECOVERY MODELS: VALLOX 90 SE R VALLOX 90 SE L DIGIT ELECTRONIC CONTROLLER WITH LCD DISPLAY...
  • Page 2: Table Of Contents

    CONTENTS EVERYDAY QUICK GUIDE VALLOX 90 SE models Code: 3520 VALLOX 90 SE has been initially adjusted for normal cir- Models cumstances in your home. Ventilation adjustment is nee- ded mainly in the following circumstances: The letter L or R after the name of the unit indicates the handedness of the unit.
  • Page 3: Three Questions About Ventilation

    VALLOX 90 SE THREE QUESTIONS ABOUT VENTILATION THREE QUESTIONS ABOUT VENTILATION SEASONAL CALENDAR 1.1. Why is air replaced in dwellings? Autumn Good ventilation promotes healthy living for both residents and the building. Air in a dwelling needs to • Wash or change the coarse filter and clean be replaced in order to remove humidity brought about by living as well as impurities or change the fine filter if needed.
  • Page 4: Ventilation Control

    2.1. Making the unit ready for operation 1. Connect the plug to the mains supply. VALLOX 90 SE is now ready for operation. 2. Turn the unit on and choose a suitable power of ventilation at the control panel. There are either one or more control panels.
  • Page 5: Ventilation Control With Carbon Dioxide Sensor

    2.4. Ventilation control with carbon dioxide sensor (option) • In carbon dioxide control, VALLOX 90 SE adjusts fan speed so as to keep carbon dioxide content in the ventilation zone below the setpoint. When two or more sensors are used, fan speed is adjusted according to the highest measuring result.
  • Page 6: Supply Air Constant Temperature Control

    • Defrost prevents the heat recovery cell from freezing, thus ensuring proper ventilation even in cold periods. • In VALLOX 90 SE defrosting is implemented by intermittently stopping the supply air fan. The stopping function is controlled on the basis of the temperature sensor measuring the temperature of exhaust air after the heat recovery cell.
  • Page 7: Fireplace Switch / Boosting

    • The points provide information on various failure modes of the unit. • When the antifrost function of the water-circulating radiator is on, the points of the relay close and open at 10-second intervals. (The VALLOX 90 SE unit does not have a water- circulating radiator.) •...
  • Page 8: Operating Menu

    VALLOX 90 SE INSTRUCTIONS FOR USING THE CONTROL PANEL Control panel Start button Scrolling up 3.1. Keyboard With this button, you switch the unit on and off. With this button, you can scroll the displays upward. When the indicator is lit, the unit is on.
  • Page 9: Settings Menu

    VALLOX 90 SE INSTRUCTIONS FOR USING THE CONTROL PANEL 3.3. Settings menu You can reach the settings menu from the operating menu as indicated in section 3.2.2. The displays of the settings menu (sections 3.3.1.–3.3.26.) can be scrolled with the scrolling buttons (see section 3.1., items 5 and 6 in the figure).
  • Page 10 VALLOX 90 SE INSTRUCTIONS FOR USING THE CONTROL PANEL 3.3.14. Adjusting the direct current fan of the supply air side The desired adjustment value for the DC fan is selected with the + and – buttons. The rotation speed DC fan - supply of the supply air fan can be lowered by decreasing the percentage value.
  • Page 11: Week Clock Control

    VALLOX 90 SE INSTRUCTIONS FOR USING THE CONTROL PANEL 3.4. Week clock control 3.4.1. Week programme programming The week programme can be used to set the desired fan speed (basic fan speed) and supply air Hr Sp temperature for each hour of the day on seven days a week. The week programme overrides Exit manual adjustments.
  • Page 12: Maintenance Instructions

    4. MAINTENANCE INSTRUCTIONS 4.1. Before starting maintenance operations When you open the door of the VALLOX 90 SE unit, the safety switch (S) switches the unit off; in spite of that, please disconnect the plug of the unit. Always disconnect the plug before starting maintenance operations for the VALLOX 90 SE unit.
  • Page 13: Fans

    VALLOX 90 SE MAINTENANCE INSTRUCTIONS 4.3. Fans Check the cleanliness of the fans in connection with the maintenance of the filter and heat recovery cell. Clean the fans if necessary. You can remove the fans from the unit before cleaning them.
  • Page 14: Troubleshooting

    VALLOX 90 SE TROUBLESHOOTING SYMPTOM REASON DO THIS Outdoor air coming to • Air cools down in the attic ducts. • Check the insulation of the attic ducts. the dwelling is cold. • The heat recovery cell is frozen, which is •...
  • Page 15 • Antifreezing of the water-circulating ra- • Immediately troubleshoot the situation. Find out from a main- diator is active (not in the VALLOX 90 SE unit). tenance company if there is non-freezing solution in the displayed and the unit is radiator.
  • Page 16 VALLOX 90 SE Vallox Oy • Myllykyläntie 9-11• FI-32200 Loimaa • Tel. +358 10 7732 200 • www.vallox.com © VALLOX • We reserve the right to make changes without prior notification.