Updating the VBD Firmware
When the VBD control panel is turned on, the first screen displayed will show the current
firmware version. If necessary the firmware in the VBD can be updated using the USB port
located below the control panel. Maguire can supply VBD firmware updates. The following
instructions detail how to do a firmware update.
Copy
the new firmware update into a USB flash drive. (do not put in a directory)
Insert
the USB Flash drive into the USB port on the VBD.
Press
SELECT
Press
ENTER
Enter
2222
Press
Press
ENTER
Press
Press
ENTER
Press
Press
ENTER
Press
ENTER
The display will show progress in transferring to the internal SD card, then it will show
progress in verifying the update file. Then the controller will prompt: "Please toggle power to
start the update process." At this time, power off the controller then on. When the controller
restarts the display will show progress in reflashing to the new firmware. When complete,
the display will show: UPDATES COMPLETE Please toggle power. At this time turn off
power, then turn back on.
Further software update information
Software updates can be supplied electronically, via email or by download. Software updates are named according to their date of release.
For instance VDM1112A.XUF can be interpreted as VD=Vacuum Dryer, M=2013 (L=2012), 11=November, 12=March 12th, A=the first revision
for that day. During the update process detailed above, new software found on the USB flash drive is first copied to an internally mounted SD
card. From the SD card, the software is then loaded into the VBD. If there is ever a problem with the VBD and the USB port cannot be used
or the VBD software is corrupted and cannot load new software through the menu, new software can be acquired from Maguire and renamed
UPDTFILE.BIN. This renamed software can be loaded onto the internal SD card and re-inserted within the VBD. When the VBD is turned on,
this UPDTFILE.BIN file will be automatically loaded into the VBD, restoring the software.
To highlight Setup Mode (gears icon).
Display will say:
MODE=SETUP
ENTER PASSWORD 0 _ _ _ _
Default password is 22222. Use the
number. Press ENTER to advance to the next digit.
to scroll the display down to System.
to select the System menu.
to scroll the display down to Update Firmware.
The display will show:
Reading from USB WAIT
and then display the update
version found on the drive.
to select the XUF file found on the Flash Drive.
to select the firmware update. If more than one .XUF file is present,
use the
to scroll down to the firmware bin file you want to use.
The display will show: Update To: VDxxxxxx.XUF Press Any
Key to Update Firmware
to start the update.
Rev. August 31, 2016 – VBD-150
buttons to adjust the
NOTE: If the VBD is not able to read from the
Flash Drive you will see this message: Error:
No Files Found. Press BACK and try again or
try a different Flash Drive.