VBD® - Vacuum Dryer®
Press:
Use the
CALIB. to do the Full Weight calibration of the
Vacuum Chamber.
Press:
ENTER to start the FULL Calibration. Press the
button to move to Continue.
Press:
Use the
Press ENTER to move between digits. ENTER to
start the FULL Calibration.
Press:
BACK multiple times to return top level menu. It is now necessary
to move the material from the Vacuum Chamber down to the
Retention Hopper. Using Manual Operations, Operation Outputs,
Ret Hop Fill, dispense the material from the Vacuum Chamber to
the Retention Hopper. Then enter the Full Calibration Routine
once again.
Press:
ENTER to start the FULL Calibration. Press the
button to move to Continue.
Press:
Use the
Press ENTER to move between digits. ENTER to
start the FULL Calibration.
46
button to move down to VT FULL
buttons to set the weight value.
buttons to set the weight value.
Rev. August 31, 2016 – VBD-150
Maguire Products, Inc.
Display will
LOADCELL FULL
show:
Enter Weight: 0_._Lb
Display will
LOADCELL ZERO
show:
-=- Wait -=-
Display will
LOADCELL FULL
show:
Enter Weight: 0_._Lb
Display will
LOADCELL ZERO
show:
-=- Wait -=-