Operating Station Overview; Controller Overview - Maguire Products VBD-150 Installation Operation & Maintenance

Vacuum dryer
Hide thumbs Also See for VBD-150:
Table of Contents

Advertisement

VBD® - Vacuum Dryer®

Operating Station Overview

Control Panel Overview
Display Screens – The VBD control panel has two screens. The upper, red display shows Actual
Temperature or Throughput. The lower, blue display shows various running mode information or setup
and configuration information.
Control Panel Power Powers on
the control panel (main power
must be ON.) Also used to exit or
cancel out of any menu option
and return to the top level screen.
Top Level Menu:
• Run Dryer - See page 19
• Run Dryer (Batch) – See page 41
• Clean Out – See page 49
• Manual Operations - See page 25
Enter selects the highlighted
menu option.
Select toggles between 4
different screen sets:
Status Screen
The Status Screen
T1a - Actual Air Temperature into the heating
hopper
T1s - Air Temperature Set-point
VTa – Vacuum Time Actual
VTs – Vacuum Time Set-point
ADV - Access to Advance Mode (page 23)
Setup Mode
Access to advanced set up information.
See Page 27
Arrow Buttons – Navigate menus, make adjustments.
alarm.
Navigating to BACK and pressing ENTER exits the current menu and back one level.
18
Displays:
Rev. August 31, 2016 – VBD-150
Maguire Products, Inc.
Print Center
For printing reports, logs, and
parameters to a USB flash drive.
See page 60.
Alarm Log
Displays a buffer of 50 of the
most recent alarm logs. Note: A
printed alarm log will print the
history of alarms since the last
clear of alarm logs.
is also used to silence the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents