VBD® - Vacuum Dryer®
Parameters
All Maguire VBD controllers operate according to certain internal PARAMETERS.
Because customer requirements vary widely, we have made parameters accessible for
change through the keypad. In most cases, these parameters will never need to be
changed. Some parameters that are routinely adjusted values are adjustable from the
main display. To access and edit the parameters, see Changing Parameters in this
section:
Changing parameters can have an impact on the Dryers performance. It is highly
recommended that a supervisor change the default Program Mode password to protect the
values. Prior to making any changes, make sure you understand what you are doing. If in
doubt contact a Maguire Dryer Technician before making changes to your dryer.
Blower Parameters:
BDT
Blower Delay Time
BLF
VFD Low Limit
BHF
VFD High Limit
BDF
VFD Frequency
BZL
VFD Zero Level
BLA
VFD Level Adjustment
BHT
VFD Heat Throttle
Dispensing Parameters:
VCH
Vac. Chamber Hi Level
VCL
Vacuum Chamber Low Level
RHH
Ret. Hopper Hi Level
RHL
Retention Hopper Low Level
BLK
Bulk Density
VFR
Vacuum Chamber Fill Rate
VDR
Vacuum Chamber Dump Rate
VFT
Chamber Fill Time
VDT
Chamber Dump Time
FLA
Fill Lag Time
DLA
Dump Lag Time
VGD
Vacuum Gate Delay
VFA
Chamber Fill Adjust
HDD
Heating Hopper Dump Delay
VCT
Vacuum Chamber Dump Threshold
CDR
Chamber Dump Reties
RAL
Residence Alarm
BCH
Batch Size
LTP
Loader Trip Point
LTC
Loader Thruput Cutoff
HHV
Heating Hopper Volume
HHU
Heating Hopper High Level
HLA
Heating Hopper Level Alarm
32
Heater Parameters:
PTS
Preheat Temperature Setting
PHT
Preheat Time
PTD
Preheat Target Delta
RTS
Run Temperature Set-Point
PT1
PD Loop Proportional
DT1
PD Loop Derivative
UT1
PD Loop Update Time
OT1
Heat1 Over-Target Alarm
NH1
Heat1 No Heat Alarm
SO1
Heat1 Set-Point Off. Percent
MP1
Heat1 Max Percent
MAX
Max Temp Set-Point
ESM
Energy Savings Mode
EST
Energy Savings Time
RMP
Temperature Ramp Settings
CTM
Cool-Down Temperature
CTR
Cool-Down Timer
Load Cell Parameters:
KDF
Loadcell Stable Wt.
LST
Load Cell Stable Time
LCZ
Loadcell Zero
WST
Weight Settle Time
LZ1
Loadcell 1 Zero
LZ2
Loadcell 2 Zero
Vacuum Parameters:
VTS
Vacuum Time Setting
VPL
Vacuum Pressure Low
VPD
Vacuum Pressure Delta
VSO
Vacuum Shutdown Offset
LVT
Low Vacuum Timeout
NVT
No Vacuum Timeout
VPT
Chamber Purge Timer
VPI
Chamber Purge Interval
ATM
Atmospheric Pressure
System Parameters:
ELT
Event Logging Time
Rev. August 31, 2016 – VBD-150