Warning And Alarm List - Grundfos CUE Series Product Manual

Frequency converters for pump control 60 hz
Table of Contents

Advertisement

Operation

Warning and alarm list

Code and display text
1
Too high leakage current
2
Mains phase failure
3
External fault
16
Other fault
30
Replace motor bearings
32
Overvoltage
40
Undervoltage
48
Overload
49
Overload
55
Overload
57
Dry running
Too high CUE tempera-
64
ture
Too high motor tempera-
70
ture
Communication fault,
77
duty/standby
89
Sensor 1 outside range
Temperature sensor 1
91
outside range
93
Sensor 2 outside range
Setpoint signal outside
96
range
Too high bearing temper-
148
ature
Too high bearing temper-
149
ature
155
Inrush fault
Temperature sensor 2
175
outside range
Relubricate motor bear-
240
ings
241
Motor phase failure
2)
242
AMA
did not succeed
1)
In case of an alarm, the CUE will change the operating mode depend-
ing on the pump type. For example: In constant pressure mode, SP's will
run at min. speed while CR's will run at 70% of max. speed.
2)
AMA, Automatic Motor Adaptation.
3)
Warning is reset in display 3.20.
In case of fault or malfunction of the CUE, the latest five
warnings and latest five alarms can be found in the log
menus.
38
Status
Operat-
Re-
ing
setting
mode
Stop
Man.
Stop
Aut.
Stop
Man.
Stop
Aut.
Stop
Man.
3)
Man.
Aut.
Stop
Aut.
Aut.
Stop
Aut.
Stop
Aut.
Stop
Man.
Stop
Aut.
Aut.
Stop
Aut.
Stop
Aut.
Stop
Aut.
Stop
Aut.
Aut.
Aut.
1)
Aut.
Aut.
1)
Aut.
Aut.
Stop
Aut.
Aut.
Stop
Aut.
Stop
Aut.
Aut.
3)
Man.
Aut.
Stop
Aut.
Man.
Warning
The CUE will continue the operation as long as the
warning is active. The warning remains active until the
cause no longer exists. Some warnings may switch to
alarm condition if the warning has been present for a
period.
Alarm
In case of an alarm, the CUE will stop the pump or
change the operating mode depending on the alarm
type and pump type.
Pump operation will be resumed when the cause of the
alarm has been remedied and the alarm has been
reset.
Resetting an alarm manually
• Press OK in the alarm display.
• Press On/Off twice.
• Activate a digital input DI 2-DI 4 set to Alarm reset
or the digital input DI 1 (Start/stop).
If it is not possible to reset an alarm, the reason may be
that the fault has not been remedied, or that the alarm
has been locked.
Locked alarm
In case of a locked alarm, the CUE will stop the pump
and become locked. Pump operation cannot be
resumed until the cause of the locked alarm has been
remedied and the alarm has been reset.
Resetting a locked alarm
• Switch off the electricity supply to the CUE for ap-
prox. 30 seconds. Switch on the electricity supply,
and press OK in the alarm display to reset the
alarm.