Connection Connectors; Note In Connecting Ccu Connector - Sony CA-950 Installation And Maintenance Manual

Camera adaptor
Table of Contents

Advertisement

1-2. Connectors and Cables

1-2-3. Connection Connectors

Connection made with the connector panels during instal-
lation or service, should be made with the connectors/
complete cable assemblies specified in the following list,
or equivalent parts.
Connector Name
Connection Connectors/Cables
PROMPTER/GENLOCK 1-569-370-12 Connector, BNC
TEST OUT
(BNC)
SERIAL IN
1-569-370-12 Connector, BNC or
SERIAL OUT
BELDEN 8281 cable equivalent
(BNC)
RET CONT
1-560-078-00 Plug, 6P Male or
(6P FEMALE)
HIROSE HR10-7PA-6P equivalent
REMOTE
1-766-848-11 Plug, 8P Male or
(8P FEMALE)
CCA-5 cable assembly (option)
CCA-5-10 (10 m)/CCA-5-3 (3 m) or
REMOTE cable 1-783-372-11
(supplied with RM-B150, 10 m)
INCOM 1/2
1-508-370-11 XLR, 5P Male or
(5P FEMALE)
CANNON XLR-5-12C equivalent
AUDIO IN 1/2
1-508-083-00 XLR, 3P Female or
(3P MALE)
CANNON XLR-3-11C equivalent
DC IN
1-508-362-00 XLR, 4P Female or
(4P MALE)
CANNON XLR-4-11C equivalent or
Cable assembly (supplied with AC-550)
1-551-577-00
DC OUT
1-566-425-11 Plug, 4P Male or
(4P FEMALE)
HIROSE HR10A-7P-4P equivalent
TRACKER
HIROSE HR25-9P-20P equivalent
(20P FEMALE)
*1: Use of REMOTE cable enables to monitor video signals.
*2: If using a cable of length different from a standard product, consult your
local Sony Sales Office/Service Center.
1-8 (E)

1-2-4. Note in Connecting CCU Connector

Before connecting this unit to the camera control unit, it is
recommendable to clean the following optical contact
portions.
For details on a cleaning method, refer to Section 2-1
"Cleaning of Connector/Cable".
. CCU connector of this unit
. CAMERA connector of the camera control unit
. Optical/Electrical cable
*2
*1 *2
CA-950/950P IMM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca-950p

Table of Contents