8.5 Mounting bracket fastening

Note
Save data when the battery has adequate residual capacity
To avoid losing measurement data that has been captured, you can transfer data to
MindSphere while the battery has sufficient residual capacity and before it is replaced.
To do this, use the "MINDSPHERE SYNC" function in the "SIMOTICS CONNECT" menu of the
"SIDRIVE IQ Config" application.
Procedure
1. Visually inspect the new battery for any damage.
2. Release the 2 central fastening screws at the front cover. You can find the relevant mounting
elements for the connectivity module in Chapter Mounting and installation (Page 15).
Do not completely turn the screws from the cover so that the screws are not lost.
3. Remove the front cover.
4. Remove the battery connector by gently withdrawing it from the socket.
5. Remove the batteries from the holder.
6. Insert the new batteries. Carefully observe the battery polarity.
7. Insert the battery connector by gently pressing on the socket provided.
8. Reattach the front cover. Carefully ensure that the cover is precisely in the correct position.
9. Tighten the 2 central fastening screws at the front cover.
10.Reenter the date and time of day:
– Automatically: Within approximately 1 minute of restarting the connectivity module, the
– Manually: Using the "SIDRIVE IQ Config" application and the "BLE name", establish a
8.5
Mounting bracket fastening
The connectivity module is mounted on a bracket in the factory. This mounting bracket is
permanently bonded to the motor. The connectivity module screwed to the mounting bracket.
You can mount the connectivity module on the opposite side of the motor if the factory mounted
position is not suitable for space reasons. To do this, use the mounting kit comprising mounting
bracket and adhesive (Page 43).
Carefully ensure that there is adequate clearance between the connectivity module and
current-carrying conductors. The center of the connectivity module should be located at the
height of the center cooling rib of the motor. When the terminal box is located at the drive end,
the center of the connectivity module should be 210 mm away from the non-drive end bearing
40
device time is automatically corrected via NTP
connection to the connectivity module. The mobile device time is transferred to the
connectivity module.