Siemens SINAMICS S120 Equipment Manual page 209

Water-cooled chassis power units for common cooling circuits
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Note
Cable lengths for versions with two dv/dt reactors
For versions with two dv/dt reactors, the cable lengths specified in the table do not change.
Table 7- 20
Technical data of the dv/dt filter plus voltage peak limiter, 500 V ... 690 V 3 AC, Part 1
Article number
Suitable for Motor Module
Type rating of the Motor
Module
I
thmax
Degree of protection
dv/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- To the Motor Module
- Load
- PE
Max. permissible cable
length between dv/dt reactor
and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage limiting network (Voltage Peak Limiter)
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- To the dv/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Water-cooled chassis power units for common cooling circuits
Manual, 08/2017, 6SL3097-4AM10-0BP0
6SL3000-
2DH31-0AA0
6SL3325-
1TG31-0AA3
kW
90
A
100
IP00
kW
0.49
kW
0.508
kW
0.541
M10
M10
M6
m
mm
350
mm
320
mm
227
kg
48
kW
0.016
kW
0.015
kW
0.013
M8
M8
M8
mm
263
mm
265
mm
188
kg
6
Motor-side power components
7.3 dv/dt filter with Voltage Peak Limiter
2DH31-5AA0
2DH32-2AA0
1TG31-5AA3
1TG32-2AA3
132
200
150
215
IP00
IP00
0.389
0.578
0.408
0.604
0.436
0.645
M10
M10
M10
M10
M6
M6
300 (shielded)
450 (unshielded)
350
460
320
360
227
275
50
83
0.020
0.032
0.019
0.03
0.018
0.027
M8
Terminal 70 mm²
M8
Terminal 70 mm²
M8
Terminal 35 mm²
263
392
265
285
188
210
6
16
2DH33-3AA0
1TG33-3AA3
315
330
IP00
0.595
0.62
0.661
M10
M10
M6
460
360
275
135
0.042
0.039
0.036
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
392
285
210
16
209

Advertisement

Table of Contents
loading

Table of Contents