Setting Mode by Jumper Wires

There are presently 2 different ways to program the operation Mode:
1) Use wire jumpers connected from ground to specified inputs.
2) Use the Set push button switch on the front panel.
This section explains method 1, using wire jumpers.
For any method of setting the Mode:
For safety, unplug or remove all Sinking Output wires, if connected. See page 26.
You must hold the Set push button pressed, apply power, and then release the button.
The Hydra will now read the Inputs 1 to 8 and add the values of grounded inputs together.
Use the DMX Port "G" terminal or the Sinking Output Port "C" terminal as the Ground.
Do not connect Input 0.
Input = Value
1 = 1
2 = 2
3 = 4
4 = 8
5 = 16
6 = 32
7 = 64
8 = 128
As an example, if inputs 1, 3 and 5 are connected to the "G" terminal:
The values add up as 1 + 4 + 16 = 21.
This would run the program Mode 21 from the table on page 4.
See a wiring example on the next page.
The Mode will be saved in memory. The Hydra will start in this Mode every time power is
applied, until you decide to set a new Mode.
If you enter a Mode that is not programmed in the Hydra, it will default to Mode 1.
Every time power is applied, the Hydra will flash the yellow LED showing the Mode that is set.
X flashes digit 1 -- Pause -- X flashes digit 2 -- Pause -- X flashes digit 3.
In a DMX Mode: The Mode will flash, then a green flash, then the DMX address will flash.