Installing the air blast limiter
Follow the instructions for this in the air surge arrester's installation
manual.

Installing the thermal hood

Follow the instructions for this in the thermal hood's installation
manual.

Connection of the air cannon to the air supply

NOTE
Always use original components supplied by Martin Engineering
for installation and operation. No liability shall be assumed for
property damage and/or personal injury due to the usage of
components and spare parts not supplied by Martin Engineering.
NOTE
The connection line between the compressed air supply and the
maintenance unit can be any length desired. The line must have
an inside diameter of at least 12 mm.
The connection line between the valve and the valve cabinet may
not exceed 30 m in length.
NOTE
Use suitable seals for all fittings.
Leaks prevent the air cannon from building up sufficient pressure
or can cause the air cannon to fire accidentally.
NOTE
Observe the applicable regulations with respect to safety valves
and gauges.
1. Attach the safety valve to the air cannon tank. Note the safety
valve's documentation for this.
2. Lay the connecting cables and pipes in accordance with the
project documentation (if provided).
27
M3727UK-09/15