© Martin Engineering GmbH
Fig. 5
1. Screw or weld the flange (B) to the connecting pipe (C).
• Screw the flange completely to the connecting pipe if the
pipe has threads. Align flange (B) with flange (A). Secure
the connection by spot-welding after aligning flange (B).
• If the connecting pipe is smooth, align flange (B) with flange
(A) depending on flange type and weld it to the pipe in
accordance with the standards or local regulations.
2. Align the air cannon tank vertically on the valve.
NOTE
If structural conditions require that the air cannon tank be installed
horizontally, then the condensation water drain nozzle must be
pointed downwards.
3. Place a seal between flanges (A) and (B) and screw the flanges
together.
NOTE
Follow the installation instructions of the respective module if
a Martin
®
Blast Guard or a manual safety slide is installed.
A
23
C
B
M3727UK-09/15