Martin TORNADO Installation Instructions Manual page 34

Air cannon
Hide thumbs Also See for TORNADO:
Table of Contents

Advertisement

© Martin Engineering GmbH
1. Determine the installation site of the solenoid valve cabinet.
2. Install the cabinet with the enclosed installation material and
withthe screw connections pointing downwards.
NOTE
Never weld the solenoid valve cabinet on directly!
3. Connect the control cables to the solenoid valve cabinet:
• Connect the control line of an air cannon to the
corresponding port on the solenoid valve cabinet. Note the
separate project documentation and cable laying diagram
(if provided).
• Connect the control cable to the control port (B, Fig. 8) of
the valve cap.
4. Connect the filling hose to the valve cap:
• Lay the filling hose of the compressed air supply (4, Fig.8)
to the valve cap.
• Connect the filling hose to the filling nozzle (A, Fig. 8) of the
valve cap.
5. Connect the maintenance unit at the inlet of the solenoid valve
cabinet and connect the compressed air supply to this as well.
NOTE
Note the direction of flow arrows on the maintenance unit, the
check valve and the ball valve when performing the installation.
6. (Optional) Fill the mist oiler with suitable pneumatic oil.
NOTE
Martin Engineering recommends using the following special oils or
alternatives in accordance with DIN 51524-HLP32:
• Klueberfood 4 NH 1-32
• Mobil Almo 525
Note the documentation for the maintenance unit for operation
with oiled compressed air.
7. Set the oiler in such a way that lubrication of the parts is
noticeable.
32
M3727UK-09/15