Air cannon
Hide thumbs Also See for TORNADO:
Table of Contents

Advertisement

Fig. 3
© Martin Engineering GmbH
6
5
4. Activating the compressed air line (1, Fig.3) causes a positive
(pressurised) signal to be sent to the venting valve (2, Fig.3).
5. Air flows into the valve head.
6. The piston (3, Fig.3) and the air inlet valve (4, Fig.3) are
actuated.
7. The valve chamber opens and the air flows out through the
valve head.
8. The piston is reset (5, Fig.3) by the pressure in the air cannon
tank.
9. The compressed air escapes choppily through the blow-off hole
(6, Fig. 3).
3
4
14
1
2
M3727UK-09/15