  • Page 1 Martin ® Air Cannon Controller - multiple circuit Operator’s Manual M4097...
  • Page 2 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION OF THE MATERIAL; USER’S FAILURE TO INSPECT, MAINTAIN AND TAKE REASONABLE CARE OF THE EQUIPMENT; INJURIES OR DAMAGE RESULTING FROM USE OR APPLICATION OF THIS PRODUCT CONTRARY TO INSTRUCTIONS AND SPECIFICATIONS CONTAINED HEREIN.
  • Page 3: Table Of Contents

    Parts Numbers ..............11 ® Martin Engineering M4097-05/18 Martin...
  • Page 4: List Of Figures

    Air Cannon Controller Dimensions......... . 12 ® Martin Engineering M4097-05/18 Martin...
  • Page 5: Introduction

    1 (e.g., if the switch disabled the controller after firing cannon 3, the sequence will start by firing cannon 1 the next time it is activated). Martin Engineering M4097-05/18 Martin ®...
  • Page 6: References

    All safety rules defined in the above documents and all owner/employer safety rules must be strictly followed when working on this equipment. Material required Only standard hand tools are required to install this equipment. Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 7: Before Installing Controller

    Before Installing Controller 1. Remove controller from shipping box. 2. If anything is missing or damaged, contact Martin Engineering or a representative. Keep any damaged goods subject to examination. WARNING Before installing equipment, lock out/tag out energy source to hopper, conveyor, and/or conveyor accessories.
  • Page 8: Installing Controller

    3. Drill conduit holes in controller enclosure for solenoid and power wires. Use care not to damage internal components. Drill in most weather-proof location available on enclosure. 4. Using electrical connectors, route wires from solenoid valves to controller enclosure. Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 9: Wiring Air Cannon Solenoids To Controller

    3. Connect power safety ground wire to terminal block labeled GND. 4. Connect power wires to terminal blocks labeled 110V and COM. Connect phase to 110V and neutral to COM. 5. Ensure ENABLE jumper is in place. Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 10: Wiring External Flow Switch To Controller

    2. To use ENABLE, do the following: a. Remove factory-installed jumpers between ENABLE terminal blocks. b. Connect external flow switch dry contact to ENABLE terminals. c. Connect external flow switch ground to controller. Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 11: After Installing Controller

    2. When finished with manual firings, return selector knob to O. (This disconnects the manual mode, and prevents accidental firing if the HAND-OFF-AUTO switch is turned to HAND.) Figure 4. Air Cannon Controller Door Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 12: Programming Controller

    Off Time Cannon #2 Off Time Off Time Cannon #3 Cannon #1 Off Time Off Time Cannon #6 Cannon #4 Off Time Cannon #5 Figure 5. Off Time Selection Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 13 Scrolls up the menu or increments the selected number. Scrolls down the menu or decrements the selected number. Goes into each control screen or enters the current operation. Figure 7. Main Display Screen Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 14: Setting Off Time

    Using the left and right arrow buttons navigate to the desired digit. d. Use the up and down arrow buttons to change the value. e. Press “OK” button to enter value. Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 15: Parts Numbers

    ® Figure 10. Martin Air Cannon Controller - multiple circuit, P/N 38901 Item Description Part No. Air Cannon Controller NEMA 4 38901 Martin Products Label 38048 Operator Manual M4097 Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 16 8.14 (207) 12.16 (309) 8.00 (203) 13.31 (338) 14.38 (365) Note: All dimensions are given in inches (mm) and are for reference only. Figure 11. Air Cannon Controller Dimensions Martin Engineering M4097-05/18 Martin ® Air Cannon Controller - multiple circuit...
  • Page 17 Any product, process, or technology described here may be the subject of intellectual property rights reserved by Martin Engineering Company. Trademarks or service marks designated with the ® symbol are registered with the U.S. Patent and Trademark Office and may be proprietary in one or more countries or regions. Other trademarks and service marks belonging to Martin Engineering Company in the United States and/or other countries or regions may be designated with the “TM”...
  • Page 18 For nearly 20 years, Martin Engineering’s Foundations™ Books have taught industry personnel to operate and maintain clean and safe belt conveyors. The Foundations™ Book, fourth edition, focuses on improving belt conveyors by controlling fugitive material. “The Practical Resource for Total Dust and Material Control,” is a 576-page hard cover volume that provides information of value to industries where the efficient handling of bulk materials is a key to productivity and profitability.