Figure 2.9 External Clock Source Connection
2.7.4

Trigger Source Connections

External Digital (TTL) Trigger
For analog input operations, an external digital trigger event occurs when the MIC-
1816 detects either a rising or falling edge on the external AI TTL trigger input signal
from screw terminals DTRG0 and DTRG1 on the screw terminal board. The trigger
signal is TTL compatible.
Figure 2.10 External Digital Trigger Source Connection
19
MIC-1816 User Manual