To remove the scanline coprocessor module, do the following and
Remove the
refer to Figure 3–7 and Figure 3–8:
Scanline
Coprocessor
1. Unscrew and remove the three screws on the mounting
2. Remove the scanline coprocessor from the four post locks by
3. Grasp the center of the scanline coprocessor module next to
4. Set the scanline coprocessor on an antistatic mat. Replace
brackets that attach the coprocessor to the system board.
The mounting brackets remain attached to the system board.
pulling back the post lock tabs.
Do not grasp the scanline coprocessor module by the
corners when you are lifting it up to remove it from the
system board. The timing buffer chip located underneath
the scanline coprocessor module can become easily
damaged by any pressure exerted on it.
the two connectors, and lift it up and off the system board.
this module after the removing Ethernet ROM.
Removing Options from a Model 40 and 48 Workstation 3–11
Removing the Ethernet ROM