Dimensions And Weight; Electrical Data - Salda RIRS EKO 3.0 1900 HE Mounting And Installation Instruction

Table of Contents

Advertisement

Warnings
• Connection of electricity and maintenance of the device should be performed only by a qualified personnel, in accordance with the
manufacturer's instructions and valid safety requirements.
• In order to reduce the risk during installation and maintenance, suitable protective clothes should be worn.
• Beware of sharp angles while performing installation and maintenance tasks.
• Do not touch heating elements until they haven't cooled down.
• Some devices are heavy, thus one should be very careful while transporting and installing. Use suitable lifting equipment.
• While connecting electricity to the mains a circuit breaker of suitable size is necessary.
Warning!
• If the device is installed in a cold environment, make sure that all connections and tubes are properly isolated. Intake and discharge air
ducts should be isolated in all cases.
• Openings of the ducts should be covered during transportation and installation.
• Make sure not to damage the heater when connecting the piping of the water heater. For tightening up, use a wrench/spanner.
Before starting the equipment
• make sure, that there are no strange objects inside;
• manually check whether fans are not stuck or blocked;
• if rotary heat exchanger is installed in the device, make sure that it is not stuck or blocked;
• check the grounding;
• make sure that all components and accessories are connected in accordance with the project or provided instructions.
Danger: Fumes
Salda Antifrost system uses dis-balancing of the air flow and it may cause negative pressure in premises. Great care should be taken
H3*
when using at the same time in premises as another heating appliance what depend on the air in premises. Such appliances include
gas, oil, wood or coal-fired boilers and heaters, fireplaces, continuous flow or other water heaters, gas hobs, cookers or ovens which
draw air in from the room and duct exhaust gases out through a chimney or extraction ducting. The heating appliance can be starved
of oxygen, impairing combustion. In exceptional cases harmful gases could be drawn out of the chimney or extraction ducting back
into the room. In this case we strictly recommend to turn off Salda Antifrost and use an external preheater for heat exchanger anti-frost
protection (see Salda Antifrost function on the Remote controller manual).

4. DIMENSIONS AND WEIGHT

L
RIRS H EKO 3.0
[mm]
1200
1350
1900
1350
2500
1610
3500
1900
5500
1910
* - depend on the unit.
m
1200 HE
1200 HW
L3
[kg]
162

5. ELECTRICAL DATA

RIRS EKO 3.0
W2
Heater
4
| EN
W3
L
L1
L
d*
L2*
L1
L1
L2*
H
H1
W
[mm]
[mm]
[mm]
[mm]
1430
-
900
235
1430
-
900
235
1710
-
1105
285
L3*
2004
-
1302
345
2008
-
1485
390
1900 HE
1900 HW
162
162
350
W1
L2
L1
D*
- phase/voltage
- power consumption
H1
W1
W
H1
W
W1
H4*
H1
H2
H3
W2*
H2
H3
H4*
H5*
[mm]
[mm]
[mm]
[mm]
235
70
105
-
H
235
70
105
-
H1
290
140
95
400
L4*
345
140
130
400
390
140
105
500
L1
RIRS EKO 3.0
2500 HE
2500 HW
3500 HE
350
350
L2
1200HE
[50 Hz/VAC]
~2, 400
[kW]
4
H
W2*
H
H2*
H
D*
W3*
D*
H5*
H
H
W2*
L
W
W1
W2*
W3*
d
L5
[mm]
[mm]
[mm]
[mm]
855
428
-
-
H2
855
428
-
-
1110
555
-
700
1205
600
-
700
1405
700
-
800
3500 HW
5500 HE
492
492
625
1200HW
1900 HE
~3, 400
AVS 315
9
RIRS 1200-5500 H EKO 3.0 v2019.06
øD*
ød*
[mm]
315
-
315
-
-
-
-
-
-
-
5500 HW
625
1900 HW
AVS 315