Page 1
1006 HE + EU - ASSEMBLY AND INSTRUCTIONS MANUAL EU - ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 1006 HE + ASSEMBLY AND INSTRUCTION MANUAL SCAN 1006 HE +...
Page 2
1006 HE + CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
CONTENTS ¬ TECHNICAL DATA Installation Product registration number Safety Dimension sketch Technical data Minimum distances Type plate ¬ ASSEMBLY Tools needed for mounting of the insert Remove packaging Loose parts Fitting the flue connection piece Additional accessories Fresh air intake Disposal of packaging Closed combustion system Room requirements...
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
Page 5
TECHNICAL DATA Test in compliance with EN 16510* Classification of appliance Type BE Nominel heat output Ŋ Energy efficiency at nominel heat output (85.5) Ŋ Seasonal space heating energy efficiency at nominel heat output s nom Energy efficiency index Energy efficiency class Fuel Wood** Fuel length, maximum...
Page 6
Minimum distances to non-combustible walls This stove is produced in accordance with type approval for the product, which also covers the product’s Assembly and Instruction Manual. Read and follow the user operating instructions carefully. The Declaration of Performance (DoP) is available from www.scan-stoves.com.
PRODUCT REGISTRATION NUMBER All Scan wood-burning stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S.
DIMENSION SKETCH Top outlet Rear outlet Centre external air supply, rear side Centre of external air supply, bottom All measures are in mm Scan 1006 Målskitse 91006001_stregtegning NAVN: EMNE: TG.NR: 03-05-2018 MATERIALE: VÆGT: DATO: SIGN: M3 NR.: DIM.: AREAL: Scan A/S...
Convection adaptors Ø149 mm (see page 18) ¬ Convection grates (See page 24) DISPOSAL OF PACKAGING Your Scan built-in stove may come supplied with the following packaging: The wood packaging can be reused and after final use can be incinerated as a CO neutral Wood packaging product or sent for recycling.
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chimney sweep, for advice. These experts will also let you know if your chimney needs renovating.
Dismount the combustion air box. This box is only needed, if the insert is to be connected with external air supply, see page 16. To remove the door: Loosen the pointed screw, Combustion air box remove the screw and the Screw spring and lift off the door spring Pointed screw Afmontage låge Scan 1005 NAVN: EMNE:...
EMNE: TG.NR: 02-05-12 DATO: MATERIALE: VÆGT: SIGN DIMENSION: AREAL: Krog Iversen & Co A/ DK-5492 Vissenbjerg C:\Working Folder\Designs\Scan 1001\91001030.idw STI: Isætning cassette Scan 1001 EMNE: TG.NR: 91001014 To ensure that the cassette is level, you can adjust 23-04-12 VÆGT: DATO:...
Page 20
NAVN: EMNE: MATERIALE: VÆG DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001013.idw STI: Mount the rawl plugs, screws and discs. Make sure that the cassette is level before fastening it. In order to fasten the insert, you can use the delivered torx key that you will find...
Page 21
DATO MATERIALE: VÆGT: DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001018.idw STI: Remove the top plate of the cassette The top plate of the cassette can be dismounted, after the cassette has been fastened. This can help facilitating the mounting of the insert...
MOUNTING OF CONVECTION GRATE (ACCESSORY) (BY BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL) Convection air grids are available as an accessory. The covering must contain holes for convection air. Convection means that there is an air circulation ensuring that the heat is equally distributed in the room.
LIGHTING We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and NOTE! keeps the combustion process clean. See our video about correct firing See our video about correct firing on www.scan-stoves.com.
CONTINUOUS OPERATION It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane.
THE FUNCTION OF THE CHIMNEY The chimney is the wood-burning stove’s motor; its performance determines how well your stove will work. The draught in the chimney creates negative pressure in the wood-burning stove. The negative pressure draws the smoke out of the stove and takes in air through the combustion air damper to fuel the combustion process.
HANDLING OF THE FUEL SELECTING WOOD/FUEL You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives. PREPARATION The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st.
Clean your wood-burning stove by wiping it down with a dry, lint-free cloth. If the paint finish gets damaged, you can purchase repair paint in spray form from your Scan dealer. As slight differences in colour shade are possible, we recommend you spray a larger area to achieve a natural blend. For best results, apply repair spray when the stove is warm, but it should preferably not be scalding hot.
TROUBLESHOOTING SMOKE ESCAPING ¬ Damp wood ¬ Chimney not drawing properly ¬ Chimney is not properly dimensioned for the stove ¬ Check if the smoke gas pipe/chimney are blocked ¬ Is the chimney the right height for its surroundings? ¬ Vacuum in room ¬...
In case of repairs that do not comply with our instructions or instructions by an authorized Scan dealer ¬ In case of any manipulation of the original state of this Scan product or its accessories. Any unauthorized modification of the stove may not be carried out ¬...
Page 40
Product registration number Quote this number at all enquiries Edition: EU 91006503 SCAN A/S Damsbovej 1 DK-5492 Vissenbjerg www.scan-stoves.com 11.11.2024...
Need help?
Do you have a question about the 1006 HE + and is the answer not in the manual?
Questions and answers