Download Print this page

Advertisement

Quick Links

1006 HE +
EU - ASSEMBLY AND INSTRUCTIONS MANUAL
EU - ASSEMBLY AND INSTRUCTIONS MANUAL
SCAN 1006 HE +
ASSEMBLY AND INSTRUCTION MANUAL SCAN 1006 HE +

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1006 HE + and is the answer not in the manual?

Questions and answers

Summary of Contents for SCAN 1006 HE +

  • Page 1 1006 HE + EU - ASSEMBLY AND INSTRUCTIONS MANUAL EU - ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 1006 HE + ASSEMBLY AND INSTRUCTION MANUAL SCAN 1006 HE +...
  • Page 2 1006 HE + CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
  • Page 3: Table Of Contents

    CONTENTS   ¬ TECHNICAL DATA Installation Product registration number Safety Dimension sketch Technical data Minimum distances Type plate   ¬ ASSEMBLY Tools needed for mounting of the insert Remove packaging Loose parts Fitting the flue connection piece Additional accessories Fresh air intake Disposal of packaging Closed combustion system Room requirements...
  • Page 4: Technical Data

    Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
  • Page 5 TECHNICAL DATA Test in compliance with EN 16510* Classification of appliance Type BE Nominel heat output Ŋ Energy efficiency at nominel heat output (85.5) Ŋ Seasonal space heating energy efficiency at nominel heat output s nom Energy efficiency index Energy efficiency class Fuel Wood** Fuel length, maximum...
  • Page 6 Minimum distances to non-combustible walls This stove is produced in accordance with type approval for the product, which also covers the product’s Assembly and Instruction Manual. Read and follow the user operating instructions carefully. The Declaration of Performance (DoP) is available from www.scan-stoves.com.
  • Page 7: Type Plate

    PRODUCT REGISTRATION NUMBER All Scan wood-burning stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S.
  • Page 8: Dimension Sketch

    DIMENSION SKETCH Top outlet Rear outlet Centre external air supply, rear side Centre of external air supply, bottom All measures are in mm Scan 1006 Målskitse 91006001_stregtegning NAVN: EMNE: TG.NR: 03-05-2018 MATERIALE: VÆGT: DATO: SIGN: M3 NR.: DIM.: AREAL: Scan A/S...
  • Page 9: Minimum Distances

    TG.NR: 02-05-12 MATERIALE: VÆGT: DATO: SIGN: Min. 500 cm DIMENSION: AREAL: Krog Iversen & Co A/S Upper DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001029.idw STI: convection opening NOTE: The flue pipe's CE-marked distance must be observed! Min. 350 cm Lower convection opening...
  • Page 10: Assembly

    Convection adaptors Ø149 mm (see page 18) ¬ Convection grates (See page 24) DISPOSAL OF PACKAGING Your Scan built-in stove may come supplied with the following packaging: The wood packaging can be reused and after final use can be incinerated as a CO neutral Wood packaging product or sent for recycling.
  • Page 11: Room Requirements

    EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chimney sweep, for advice. These experts will also let you know if your chimney needs renovating.
  • Page 12: Trims And Doors

    SAFETY DISTANCE European, national and local regulations concerning safety distances for wood-burning stoves and flue pipes must be complied with. Pakning på svøb 91001036 EMNE: TG.NR: DATO: 11-05-12 VÆGT: SIGN: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© Folder\Designs\Scan 1001\91001036.idw...
  • Page 13: Operating The Door

    Dismount the combustion air box. This box is only needed, if the insert is to be connected with external air supply, see page 16. To remove the door: Loosen the pointed screw, Combustion air box remove the screw and the Screw spring and lift off the door spring Pointed screw Afmontage låge Scan 1005 NAVN: EMNE:...
  • Page 14 Afmontage røgstuds Scan 1005 EMNE: TG.NR: 91005004 13-03-2018 ALE: VÆGT: DATO: SIGN: SION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© :\Working Folder\Designs\Scan 1005\91005004.idw Afmontage ovn fra svøb Scan 1005 91005005 NAVN: EMNE: TG.NR: DATO: 13-03-2018 MATERIALE: VÆGT: SIGN: DIMENSION: AREAL: Krog Iversen &...
  • Page 15: Fitting The Flue Connection Piece

    91001025 NAVN: EMNE: TG.NR: MATERIALE: VÆGT: DATO: 26-04-12 SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001025.idw STI: Montage røgstuds an 1001 91001025 EMNE: TG.NR: FRESH AIR INTAKE 26-04-12 VÆGT: DATO: SIGN: AREAL: Krog Iversen & Co A/S In a well-insulated house, the air used up by the burning process has to be replaced.
  • Page 16: Mounting Of External Air Supply

    EMNE: Krog Iversen & Co A/S TG.NR: MATERIALE: VÆGT: DATO: 07-05-2012 SIGN: DK-5492 Vissenbjerg© Working Folder\Designs\Scan 1005\91005009.idw DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001032.idw STI: Mount the Ø100 sleeve Ekstern forbrænding bag på svøb an 1001...
  • Page 17 NAVN: EMNE: TG.NR: 91001032 07-05-2012 MATERIALE: VÆGT: DATO: SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001032.idw STI: Mount the Ø100 sleeve Scan 1001 Frisklufttilførsel bund af ovn 91001032 NAVN: EMNE: TG.NR: 07-05-2012 MATERIALE: VÆGT: DATO:...
  • Page 18: Fitting Without The Convection Connection Pieces

    Krog Iversen & Co A/S DK-5492 Vissenbjerg© FITTING THE CONVECTION CONNECTION PIECES (ACCESSORY) C:\Working Folder\Designs\Scan 1005\91005017.idw STI: Convection connection pieces Ø149 mm To dismount the cover plates for the convection adaptors, use an slotted screwdriver as shown below. Tilt the screwdriver and loosen the cover plates.
  • Page 19: Fitting The Cassette

    EMNE: TG.NR: 02-05-12 DATO: MATERIALE: VÆGT: SIGN DIMENSION: AREAL: Krog Iversen & Co A/ DK-5492 Vissenbjerg C:\Working Folder\Designs\Scan 1001\91001030.idw STI: Isætning cassette Scan 1001 EMNE: TG.NR: 91001014 To ensure that the cassette is level, you can adjust 23-04-12 VÆGT: DATO:...
  • Page 20 NAVN: EMNE: MATERIALE: VÆG DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001013.idw STI: Mount the rawl plugs, screws and discs. Make sure that the cassette is level before fastening it. In order to fasten the insert, you can use the delivered torx key that you will find...
  • Page 21 DATO MATERIALE: VÆGT: DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001018.idw STI: Remove the top plate of the cassette The top plate of the cassette can be dismounted, after the cassette has been fastened. This can help facilitating the mounting of the insert...
  • Page 22: Mount The Insert In The Cassette

    91001027 AVN: EMNE: TG.NR: 26-04-2012 MATERIALE: VÆGT: DATO: SIGN: IMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001027.idw Grip holes for pivot pins Styretapper og fanghuller Scan 1001 NAVN: EMNE: TG.NR: 91001017 24-04-12 MATERIALE: VÆGT: DATO: SIGN:...
  • Page 23: Mounting Of The Trim

    DIMENSION: AREAL: Krog Iversen & Co A/S DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001031.idw STI: DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001031.idw STI: Remount the top plate of the cassette and the door MOUNTING OF THE TRIM We recommend that you do not mount the trim, until the insert has been approved by the chimney sweep, as he may demand to see the type plate which is situated on the top plate of the cassette (to dismount the top plate, see page 21).
  • Page 24: Mounting Of Convection Grate

    MOUNTING OF CONVECTION GRATE (ACCESSORY) (BY BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL) Convection air grids are available as an accessory. The covering must contain holes for convection air. Convection means that there is an air circulation ensuring that the heat is equally distributed in the room.
  • Page 25: Mounting Of Catalyst

    DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005044.idw IMPORTANT ! Wear a glove when handling the stove. STI: In order not to limit the effect of the catalytically active layer, the catalyst must only be handled with gloves, preferably disposable gloves.
  • Page 26: Mounting Of Combustion Chamber

    NSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005021.idw C:\Working Folder\Designs\Scan 1005\91005020.idw STI: Mount the right rear plate. The rear burn chamber Mount the right burn chamber plate plates must be mounted so that the holes of the plates are placed precisely over the tertiary holes of the insert Montering af brændkammerbeklædning...
  • Page 27 NAVN: EMNE: TG.NR: 91005024 21-03-2018 MATERIALE: VÆGT: DATO: SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005024.idw STI: af nederste røgvenderplade 91005024 TG.NR: 21-03-2018 VÆGT: DATO: SIGN: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© 24.idw Montering af nederste røgvenderplade...
  • Page 28: Adjustment Of The Door

    DIMENSION: AREAL: Krog Iversen & Co A/S The door is delivered without self-closing DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005032.idw STI: function (Bauart 1). If you want a self-closing door, the spring can be tightened by turning the long screw (inside the spring) counter-clockwise using...
  • Page 29: Instructions For Use

    Adjustment of air supply, primary and secondary damper CB-technique Primary air 0%-100% 0%-100% Tertiærkasse, luftindikator Scan 1005 91005014 NAVN: EMNE: TG.NR: 19-03-2018 MATERIALE: VÆGT: DATO: SIGN: Primary air Secondary air DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005014.idw STI:...
  • Page 30: Iinstructions For Heating

    LIGHTING We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and NOTE! keeps the combustion process clean. See our video about correct firing See our video about correct firing on www.scan-stoves.com.
  • Page 31: Continuous Operation

    CONTINUOUS OPERATION It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane.
  • Page 32: The Function Of The Chimney

    THE FUNCTION OF THE CHIMNEY The chimney is the wood-burning stove’s motor; its performance determines how well your stove will work. The draught in the chimney creates negative pressure in the wood-burning stove. The negative pressure draws the smoke out of the stove and takes in air through the combustion air damper to fuel the combustion process.
  • Page 33: Selecting Wood/Fuel

    HANDLING OF THE FUEL SELECTING WOOD/FUEL You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives. PREPARATION The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st.
  • Page 34: Combustion Chamber Lining

    Clean your wood-burning stove by wiping it down with a dry, lint-free cloth. If the paint finish gets damaged, you can purchase repair paint in spray form from your Scan dealer. As slight differences in colour shade are possible, we recommend you spray a larger area to achieve a natural blend. For best results, apply repair spray when the stove is warm, but it should preferably not be scalding hot.
  • Page 35: Cleaning The Glass

    Baffle plate Ceramic stone and chamotte are not recyclable. Dispose of as waste DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005012.idw STI: Gaskets Dispose of as waste Catalyst Return the used catalyst to Scan via the dealer...
  • Page 36: Troubleshooting

    TROUBLESHOOTING SMOKE ESCAPING ¬ Damp wood ¬ Chimney not drawing properly ¬ Chimney is not properly dimensioned for the stove ¬ Check if the smoke gas pipe/chimney are blocked ¬ Is the chimney the right height for its surroundings? ¬ Vacuum in room ¬...
  • Page 37: Warranty

    In case of repairs that do not comply with our instructions or instructions by an authorized Scan dealer ¬ In case of any manipulation of the original state of this Scan product or its accessories. Any unauthorized modification of the stove may not be carried out ¬...
  • Page 38 NOTES...
  • Page 40 Product registration number Quote this number at all enquiries Edition: EU 91006503 SCAN A/S Damsbovej 1 DK-5492 Vissenbjerg www.scan-stoves.com 11.11.2024...