Huawei VP9660 Quick Start Manual page 22

Hide thumbs Also See for VP9660:
Table of Contents

Advertisement

HUAWEI VP9660
Quick Start Guide
Table 2-6 Connections between power cables and wiring terminal sockets
Wiring Terminal
Socket
RTN (+)
NEG (-)
Step 2 Use a multimeter to measure the resistance between the NEG (-) and RTN (+) wiring terminal
sockets.
If the resistance is greater than or equal to 10 ohms, the power cables are connected properly.
If the resistance is less than 10 ohms, a short circuit is occurring. In this case, locate the cause
and reconnect the power cables to the wiring terminal sockets.
Step 3 Connect the other end of the power cables to the power supply device in the equipment room.
Step 4 Check the output voltage of the power supply device and turn on the power switch of the
device.
Step 5 Check whether the following conditions are met:
If the preceding conditions are not met, reconnect the power cables.
----End
Connecting a Power Cable to an AC Power Module
The AC power module provides a power socket in the lower left corner of its front panel. The
power socket uses an International Electrotechnical Commission (IEC) C14 inlet and has a
power plug lock.
Step 1 Pull upward on the power plug lock on the left of the power socket, as shown in
Issue 04 (2013-12-30)
Cable Name
Power cable
Power cable
The difference between the power supply device's output voltage and the voltage
between the RTN (+) and NEG (-) wiring terminal sockets is less than 2 V.
The power cables are correctly connected to positive and negative terminals of the power
module.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Installing the VP9660
Cable Color
Black
Blue
Cable Connector
Cord end terminal
Figure
2-10.
18