Entrematic Ditec EL21 Installation Manual page 9

For ditec valorr-tenr automations installed in escape routes
Table of Contents

Advertisement

Command
1
KC
NO
1
G1
NO
G2
1
S1
NO
1
AO
NO
NO
OPEN
Function
KEY CLOSING
GENERAL PURPOSE
GENERAL PURPOSE
CONNECTION OF
MICROSWITCH
AUXILIARY
OPENING
OPENING
SETTINGS RESET
Description
The closing operation starts when the contact is closed.
If the door is set to NIGHT-TIME CLOSURE mode, the
KEY CLOSING command, given after opening with the
1-KO command, will close the door and immediately
restore the NIGHT-TIME CLOSURE mode.
N.B.: this command can be combined with a key to allow
immediate reclosing of a shop door set to NIGHT-TIME
CLOSURE mode.
Disabling /enabling of COMER function selector switch.
Make connection, as described on page 24.
FUTURE USE
Connect block microswitch as described on pages 24-
25.
Contact closure activates the opening operation.
If the operation as escape route is disabled, it will be
re-enabled for 5 minutes (or for the time set by the
display module MD1).
N.B.: This command can be combined with a magnetic
card reader for access to automated teller machines if
the door is set to NIGHT-TIME CLOSURE mode .
Press quickly to activate opening operation.
Keep the OPEN button pressed (for 4 s), until the IN
LED starts to flash. To confirm the operation, press the
OPEN button again for 2 seconds within 4 seconds.
The SETTINGS RESET deletes all the remote software
settings made using the DMCS software, the MD1 dis-
play module and the COMER selector.
N.B.: We recommend carrying out the SETTING RESET
during starting (see section 11), or whenever the COM-
ER selector is replaced with a COMKR selector.
27