Adjustments; Dip-Switches; Signals - Entrematic Ditec EL21 Installation Manual

For ditec valorr-tenr automations installed in escape routes
Table of Contents

Advertisement

7.

Adjustments

i
Make adjustments as explained in the MD1 display module installation manual

7.1 Dip-switches

DIPs
Description
DIP1
Block type
DIP2
FUTURE USE
DIP3
Door wing weight
DIP4
FUTURE USE
7.2

Signals

LED
On
POWER
Power supply on.
SA
Indicates that at least one of the safety con-
tacts is open.
IN
A total or partial opening command or clos-
ing command is received.
BUZZER
Event
Escape route test
Alarm signalling
COMER selector enabled
OFF
VALLOKB
/
<200 kg
/
30
ON
No block
/
>200 kg
/
Flashing light
Encoder not working or automa-
tion faulty.
Safety test failure (terminal 41).
The dip switch or COMKR selector status
changes
SETTINGS RESET in pro-
SETTINGS RESET in pro-
gress.
Effect
1 acoustic signal every second
5 acoustic signals every minute
6 acoustic signals every 10 seconds

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents