5. Commands

WARNING: make a jumper for all NC contacts if not in use. The terminals with the
same number are equal.
Command
0 1 R+ R- 8A 41
0 1
8A 41
41
8A NC
1
3B NO
41
8B NC
41
6A NC
41
6B NC
1
EO
NC
1
KO
NO
Function
INNER SIDE
OPENING
REVERSAL
SAFETY CONTACT
OUTER SIDE OPENING
REVERSAL
SAFETY CONTACT
LH SIDE OPENING
SAFETY DEVICE
OPENING SAFETY
DEVICE - RH SIDE
EMERGENCY
OPENING
KEY OPENING
Description
Connect an autocontrolled safety sensor model
PAS024AMT (or equivalent) as described on pages 24-
25 or in section 10.
N.B.: terminals R+/R- are a current input.
Check on sensor PAS024AMT that the activation output
is set to CURRENT [5].
For further information refer to the PAS0AM24T sensor
installation manual.
Opening the contact triggers a reversal of motion (re-
opening) during closing.
Contact closure activates the opening operation.
Opening the contact triggers a reversal of motion (re-
opening) during closing.
The opening of the contact causes the opening speed
to decrease in the last 500 mm of stroke of the door
wing.
Presence sensors can be connected as well, as de-
scribed in section 9.
Advanced command management is available with the
MD1 display module. See function
Opening the contact activates emergency opening
operation. This command is active in every situation
(also in NIGHT-TIME CLOSURE mode) and has prior-
ity over every other command. When the contact has
closed again, the door goes back to working as set by
the COMER or COMKR selector.
N.B.: this command can be combined with an emer-
gency button.
Contact closure activates the opening operation.
If the door is set to NIGHT-TIME CLOSURE mode,
the KEY OPEN command will carry out the opening
operation and activate door operation in TWO-WAY
mode (or for the time set by the MD1 display module).
).
N.B.: this command can be combined with a key to
allow evening exiting or morning entry through a shop
door set to NIGHT-TIME CLOSURE mode.