6. Outputs and accessories

Output
0 1 R+ R- 8A 41
REMOTE
0 1 21
22
ROTARY FUNCTION
SELECTOR
1 2 A B 9 27 29
COM
+
MOT
-
+
MOT2
-
ENC
POWER
Value /
Accessories
Accessories power supply. External accessories power sup-
ply output.
24 V
0.5 A (max)
N.B.: the maximum absorption of 0.5 A corresponds to the
sum of all terminals 1.
Allows connection of the COMER selector and MD1 display
for distances of up to 50 m.
N.B.: use a data transmission type screened cable.
COMER
Connect the shielding to the earthing.
MD1
N.B.: If firmware needs updating, connect the DMCS device
to the DMCS JACK on the function selector switch. When the
operation has been completed, disconnect the DMCS device
and perform a POWER RESET.
It allows COMKR selector connection, as described on page
25.
COMKR
N.B.: connect terminals 21-22 (REMOTE) to the DMCS jack
on the COMKR selector using a data transmission type
shielded cable.
This allows the functioning configurations to be saved us-
ing the
The saved configurations can be recalled via the
BIXMR2
If the control panel is replaced, the BIXMR2 storage module
being used can be inserted in the new control panel.
WARNING: the storage module must be inserted and re-
moved with the power supply disconnected.
Motor connection.
Connect the double winding motor to the control panel using
the supplied cables as described on pages 24-25.
Encoder connection.
Connect the encoder to the control panel using the supplied
cables as described on pages 24-25.
Power supply unit connection, as described on pages 24-25.
AL2
Description
function of the MD1 display module.
function of the MD1 display module.
28