Escape Route Sensor; Autocontrolled Safety Sensor - Entrematic Ditec EL21 Installation Manual

For ditec valorr-tenr automations installed in escape routes
Table of Contents

Advertisement

8 Escape route sensor

On sliding doors used in escape routes, the open-
ing on the exit direction shall be controlled by an
autocontrolled safety sensor model PAS024AMT (or
equivalent).
If you use a PAS024AMT sensor, make connections as
indicated on pages 24-25.
Check that the activation output is set to CURRENT [5]
(see PAS024AMT installation manual).

9. Autocontrolled safety sensor

Autocontrolled safety devices can be connected as shown in the figure.
Set DIP10=ON on each PASAT3.
A
A
24V
- +
1 2
3 4 5 6
B
24V
- +
1 2
3 4 5 6
0 1 6A 6B 41
OPEN SAFETY
31
yellow/black
YELLOW/BLACK
white/black
WHITE/BLACK
0 1 R+ R-
INTERNAL
INTERNAL
SENSOR
SENSOR
B