Good Faith TV Guidelines
Good Faith Guidelines for TV Installations
Above a Fireplace with Passive Heat Option
This diagram specific to these models:
WARNING! Risk of Fire!
greater than 3 inches. Secure mesh to top of framing.
ROOM CEILING
SEE FIGURE 3.7, 3.8, 3.9
DIMENSION B
(MINIMUM CLEARANCE TO FRAMING)
82 IN. MIN.
Measurement from top edge
of opening to bottom of
appliance = 25-7/8 IN.
*
Mesh screen required for front discharge or open top discharge passive heat installations with discharge
opening of three inches or greater.
Mesh screen recommended for front discharge or open top discharge passive heat installations with discharge
opening of less than three inches.
NOTE: The TV installation requirements are the same regardless of whether the Passive Heat kit is installed with a
top discharge, side discharge or open top discharge.
Figure 10.16 Good Faith Guidelines for TV Installations Above a Fireplace with Passive Heat Option
Majestic • JADE32IN-B, JADE42IN-B, JADE42IL-B Installation Manual • 2619-986 Rev. B • 10/19
66
Wire mesh required on bottom of discharge opening when discharge opening is
1-1/2 IN. (2 X 4 FRAMING)
2 IN. MIN.
4 IN. MIN.
1/2 IN. X 1/2 IN.
WIRE MESH*
2 X 4 FRAMING
2 X 4 OR 2 X 6
FRAMING
TV
12 IN. MIN.
JADE32IN-B
JADE42IN-B
JADE42IL-B
CHASE CEILING (1/2 INCH WALL SHEATHING/FINISHING MATERIAL)
REQUIRED FOR FRONT AND SIDE DISCHARGE
CANNOT BE INSTALLED ON OPEN TOP DISCHARGE
WIRE MESH*
= PASSIVE HEAT
DISCHARGE OPENING
FIREPLACE
OPENING