Framing
This appliance is designed to be recessed into combus-
tible framing with non-combustible material pre-installed
on top and side. Drywall or combustible materials (mini-
mum 1/2 inch thick) are designed to contact the non-
combustible material/appliance as called out in Section
10 Finishing.
This appliance has been thoroughly tested to minimize
drywall cracking and/or the protrusion of screws "screw
pops" when framed as shown below.
Framing should be done in a manner similar to framing a
window or door: Double-2x4/2x6 as a header for horizon-
tal strength and utilizing Jack or Trimmer stud fastened to
the King studs for vertical strength.
Note: Header MUST be installed on end
as shown in the diagram.
HEADER: TWO 2 X 4'S OR 2 X 6'S
JACK (TRIMMER) STUD
A
Model
Rough
Size
Opening
(Vent Pipe)
in.
8-5/8
32
mm
219
in.
8-5/8
42
mm
219
* Adjust framing dimensions for interior chase sheathing (such as sheetrock)
Figure 3.6
Clearances to Combustibles
Majestic • JADE32IN-B, JADE42IN-B, JADE42IL-B Installation Manual • 2619-986 Rev. B • 10/19
14
A
INSTALLED ON END
B
C
D
KING STUD
MINIMUM FRAMING DIMENSIONS*
B
C
D
Rough
Rough
Rough
Opening
Opening
Opening
(Height)
(Depth)
(Width)
36-1/2
17-3/4
37
927
451
940
32-3/4
17-3/4
49
832
451
1245
If elevating the appliance, the base of the appliance
should also be constructed in a similar manner to prevent
settling.
Refer to Figures 3.7, 3.8 and 3.9 for information regarding
framing when the Passive Heat Kit is installed. Install the
Passive Heat Kit per the instructions provided with the kit.
Note: Refer to Section 10 for important information
related to facing, drywall specifications and decorative
barrier front information.
G
NOTE: E & K dimensions will change if
Passive Heat option is installed. Reference the
instructions included with the Passive Heat Kit.
E
F
G
Clearance
Combustible
Minimum
to Room
Floor
Hearth
Ceiling
Required
31
0
0
787
0
0
31
0
0
787
0
0
MEASURE FROM TOP
OF APPLIANCE OPENING
H
I
J
H
I
J
Behind
Sides of
Front of
Appliance
Appliance
Appliance
1/2
1/2
36
13
13
914
1/2
1/2
36
13
13
914
E
K
K
Clearance
to Ceiling
56-7/8
1445
56-7/8
1445

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jade42in-bJade42il-bJade32inJade42inJade42il

Table of Contents