Hide thumbs Also See for JADE32IN:
Table of Contents

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JADE32IN and is the answer not in the manual?

Questions and answers

Summary of Contents for Majestic JADE32IN

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 2: Table Of Contents

    C. Securing and Leveling the Appliance ....36 D. Non-Combustible Material Installation ....37  = Contains updated information. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2491-988 9/17 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 4: Product Specific And Important Safety Information

    Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 5: Non-Combustible Materials Specification

    State of California to cause cancer and reproductive harm. For more information go to: www. P65Warnings.ca.gov. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 7: Getting Started

    Electric drill and bits: (1/4 in./Phillips #2) Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 8: Inspect Appliance And Components

    Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 9: Framing And Clearances

    Millimeters Location Inches Millimeters 16-3/4 6-5/8 27-1/4 34-3/8 15-1/4 2-3/16 38-1/16 3-1/2 17-1/4 25-7/8 1041 38-1/2 9-13/16 17-3/4 10-5/8 25-3/4 7-3/4 Figure 3.1 Appliance Dimensions - JADE32IN Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 10 16-3/4 1219 6-5/8 1092 32-3/8 39-1/16 2-3/16 15-1/4 33-11/16 17-1/4 3-1/2 25-7/8 47-1/16 1195 50-1/2 1283 9-13/16 17-3/4 10-5/8 37-3/4 7-3/4 Figure 3.2 Appliance Dimensions - JADE42IN/JADE42IL Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 11 14-1/8 33-1/8 6-7/8 9-13/16 19-7/8 26-7/8 JADE32IN CFT-32 40-3/16 14-1/8 45-1/8 6-7/8 9-13/16 19-7/8 26-7/8 JADE42IN CFT-42 JADE42IL 1021 1146 Figure 3.3 Decorative Front Dimensions - CFT Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 12 14-1/8 37-1/2 4-5/8 9-7/8 24-7/16 29-1/8 JADE32IN PFF-32 40-3/16 14-1/8 49-7/16 4-5/8 9-3/4 24-7/16 29-1/16 JADE42IN PFF-42 JADE42IL 1021 1255 Figure 3.4 Decorative Front Dimensions - PFF Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 13: Clearances To Combustibles

    15-1/16 17-1/4 JADE32IN Millimeters 1134 1603 See Section 10.C for Alcove Installation. Inches 50-1/2 71-1/2 19-1/2 17-1/4 JADE42IN JADE42IL Millimeters 1283 1245 1816 Figure 3.5 Appliance Locations Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 14 (Depth) (Width) 8-5/8 36-1/2 17-3/4 JADE32IN 8-5/8 32-3/4 17-3/4 JADE42IN JADE42IL 1245 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 3.6 Clearances to Combustibles Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 15: Constructing The Appliance Chase

    • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace may cause overheating and a fire. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 16: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof to Lowest Discharge Opening Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 17: Chimney Diagram

    2 sides beneath the floor. venting system does not meet these requirements. • Vinyl protection kits are suggested for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 18: Approved Pipe

    WARNING! Risk of Fire or Asphyxiation. This appli- ance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 19: Use Of Elbows

    Figure 4.5 Vertical and Horizontal Offset for SLP Elbows SLP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 SLP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.4 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 20: Measuring Standards

    • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.6 Measure to Outside Mounting Surface Figure 4.7 Measure to Top of Last Section of Pipe Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 21: Use Of Flex Vent (Slp-Flex Series 6-5/8 Inch)

    3 in. CLEARANCE released. See Figure 4.9. FLEX-VENT 1 in. CLEARANCE 1/4 in. max. (6 mm) Figure 4.8 Flex Vent Pipe - Generic Fireplace Shown Figure 4.9 Vent Cap Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 22 CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. Figure 4.10 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 23 CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. INSTALLED HORIZONTALLY Figure 4.11 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 24 CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. Figure 4.12 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 25 MAX. = 15 ft. (4.6 m) MAX. = 7 ft (2.1 m) glass breakage. INSTALLED HORIZONTALLY INSTALLED HORIZONTALLY Figure 4.13 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 26 Note: Use SLP Series components only. Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed. Figure 4.14 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 27 3. JADE42IN/JADE42IL Only: Reinstall shield by secur- ing it with the two wing nuts and two screws previously removed in Step 1. EXHAUST RESTRICTOR INSTALLED SCREWS Figure 4.15 Installing Restrictor Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 28 H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. Note: Use SLP Series components only. Figure 4.16 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 29 Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. INSTALLED HORIZONTALLY Figure 4.17 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 30 Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. Figure 4.18 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 31 DV-46DVA-GCL adapter and LINK-DV30B • Installer MUST install the 3 ft. stainless steel flex on kit. This could result in poor flame appearance, sooting, JADE32IN. pilot malfunction, or overheating. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 32 EXISTING CHIMNEY To minimize cold air drafts, seal with non-combustible insulation. DIRECT VENT FIREPLACE Minimum 10 ft. 3.05 m Maximum 40 ft. 12.2 m HEARTH FLOOR Figure 4.21 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 33: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is 1 in. (25 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 34: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 35: Appliance Preparation

    IN POSITION KNOCKOUT LOCATIONS (RIGHT & LEFT SIDES) Figure 6.2 JADE42IN/JADE42IL - Top Heat Shield in Position Figure 6.4 JADE32IN - Shipping Support and Seal Cap Removed Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 36: Installing Optional Heat Management Systems

    FACTORY-INSTALLED NON-COMBUSTIBLE BOARD DO NOT REMOVE NAILING TABS BOTH SIDES Figure 6.5 Proper Positioning, Leveling And Securing Of Appliance Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 37: Non-Combustible Material Installation

    Refer to Section SCREWS INTO 10 for more information. THESE PILOT HOLES NOTE: BOTH LEFT & RIGHT SIDES Figure 6.7 Installation of the Side Non-Combustible Components Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 38: Venting And Chimneys

    Use care when remov- ing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent could leak. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 39: Assemble Slip Sections

    “Assembling Pipe Sections.” NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 40: Secure The Vent Sections

    Figure 7.7 Rotate Seams for Disassembly connection point to appliance. 120º Figure 7.8 Align and Disassemble Vent Sections Figure 7.5 Securing Vertical Pipe Sections 120º Figure 7.6 Securing Horizontal Pipe Sections Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 41: Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.10. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 42: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Figure 7.12 Important Notice: Heat shields may not be fi eld constructed. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 43 CAUTION! Risk of Burns! Local codes may require in- INTERIOR EXTERIOR stallation of a cap shield to prevent anything or anyone from touching the hot cap. Figure 7.13 Venting Through the Wall Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 44: Electrical Information

    BOTTOM PANEL SCREW LOCATIONS ground attached GRN wire to GRN screw with inside box GRN wire Figure 8.1 Remove Lower Access Panel Figure 8.4 Junction Box Wiring (Generic Model Shown) Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 45: Wiring Requirements

    Do not store batteries in the battery pack when the appliance is powered by the 6 volt transformer connected to permanent electrical service. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 46 VALVE (NG) 2326-134 2166-302 JUMPER 2187-198 ORANGE DETAIL A GROUND TO FIREPLACE CHASSIS GREEN WHITE WIRE ASSEMBLY 2118-170 BATTERY PACK Figure 8.5 Intellifire™ Touch Wiring Diagram - Standard Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 47 CONTROL IFT-RC150 WIRELESS 6V DC WALL SWITCH BATTERY PACK 2326-134 LED-LINEAR Components shown in diagram. Figure 8.6 Intellifire™ Touch Wiring Diagram with Remote, Fan and LED Options Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 48 2155-033 PVI-WH20 PVI-WH40 PVI-WH60 ORANGE PVI-WH80 PVI-WH100 GROUND TO FIREPLACE CHASSIS PVI-SLP-B OR PVLP-SLP GREEN PVLP-SLP PVI-SLP-B Figure 8.7 Intellifire™ Touch Wiring Diagram with Power Vent Diagram Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 49: Gas Information

    1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Figure 9.1 Base Pan Removal - JADE42 Shown Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 50 There is limited access to the pressure taps after finishing material installation. Remove glass assembly and utilize an appropriate sized screwdriver. REMOVE BURNER SCREW Figure 9.2 Burner Removal Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 51: Gas Connection

    Figure 9.5 Air Shutter Location Air Shutter Settings JADE32IN (NG) 1/16 in. JADE32IN (PROPANE) 1/8 in. JADE42IN (NG) 1/16 in. JADE42IL (PROPANE) 3/16 in.  Figure 9.4 Incoming Gas Line Location Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 52: Finishing

    • Facing and/or finishing materials must not interfere with air flow through decorative fronts. • Facing and/or finishing materials must never overhang into the glass opening. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 53: Non-Combustible Board And Drywall Installation

    PVA expected. If a blemish begins to show over a screw head, primer. sand the surface to remove the blemish and repaint. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 54 3 inch edges of the factory-installed non-combustible board to secure the drywall adjacent to the factory-installed non-combustible board. See Figure 10.2. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 55: Mantel And Wall Projections

    TO TOP OF APPLIANCE OPENING APPLIANCE OPENING Figure 10.4 Clearances To Non-Combustible Mantels Or Other Non-Combustibles Above Appliance Figure 10.3 Clearances To Combustibles Mantels Or Other Combustibles Above Appliance Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 56 7 IN. MIN. WALL APPLIANCE OPENING UNLIMITED Figure 10.6 Combustible or Non-Combustible Mantel Leg or Wall Projections - Unlimited Wall Length (Acceptable on both sides of opening) Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 57: Decorative Front Finishing

    DECORATIVE FRONT (TOP EDGE) Finishing materials 1 inch maximum thick. Stop finishing material flush with opening. Figure 10.7 Overlap Fit Decorative Front (CFT and PFF Decorative Fronts) Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 58 Figure 10.9 Maximum Finish Material Thickness - CFT Decorative Front INNER DECORATIVE FRONT ASSEMBLY TOP VANITY PANEL (NOT SHOWN) Figure 10.11 CFT Front Installation With Outer Decorative Front Trim Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 59 0 IN. (CFT) Figure 10.12 Clearances to Appliance Opening Without Outer Decorative Front Trim (BOTH SIDES) (BOTH SIDES) Figure 10.13 CFT Front Without Outer Decorative Front Trim Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 60: Appliance Setup

    Clean/vacuum any sawdust that may have accumulated JADE42IN/JADE42IL and JADE32IN models. Install the inside the firebox or underneath in the control cavity. glass refractory per instructions included with the kit. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 61: Install Led Lights (Optional)

    WARNING! Risk of Explosion! Risk of Asphyxiation! Glass latches MUST be properly engaged. Inspect glass seal before installing decorative front. Gas could leak! 5. Reinstall decorative front. Figure 11.2 Media Placement Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 62: Install Decorative Front

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 63: Reference Materials

    1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 12.1 SLP Series Vent Components Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 64 14-7/16 in. 12-5/8 IN. 10-5/8 IN. 59 mm 367 mm (321 mm) (270 mm) SLP-RDS SLP-WT-BK ROOF DECK INSULATION SHIELD Wall Thimble-Black Figure 12.2 SLP Series Vent Components Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 65 7-3/4 to 10-3/8 in. 343 mm 121 mm (197 to 264 mm) DVP-FBHT Horizontal Termination Cap SLK-SNKD (SL-2DVP Required) Snorkel Termination Cap Figure 12.3 SLP Series Vent Components Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 66 COAXIAL to COLINEAR VENTING LINK-DV30B 768-380A DV-46DVA-GCL Flex Liner Kit Stainless Steel Flex Pipe Coaxial/Colinear Appliance Connector (Required on JADE32IN) Figure 12.5 Coaxial to Colinear Vent Components Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 67 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. (318 mm) SLP-LPC SLP Low Profile Cap (Approved for use with PVI-SLP-B only) Figure 12.6 PVI-SLP-B Vent Components Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 68 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.7 PVLP-SLP Vent Components Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...
  • Page 69: Accessories

    Please contact your Majestic dealer with any questions or concerns. For the location of your nearest Majestic dealer, please visit www.majesticproducts.com. Printed in U.S.A. - Copyright 2018 Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18...

This manual is also suitable for:

Jade42inJade42ilJade42

Table of Contents