Measuring Standards:
Vertical and horizontal measurements listed in the vent
diagrams and clearances for termination were made
using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Section 12.A (Figure 12.1) for information
on effective length of pipe components.
• Horizontal terminations are measured to the outside
mounting surface (flange of termination
Figure
4.7.
• Vertical terminations are measured to top of last section
of pipe. See Figure 4.8.
• Horizontal pipe installed level with no rise.
• Horizontal and vertical termination clearances measured
to trapezoid portion of cap. See Figure 4.3.
Figure 4.7 Measure to Outside Mounting Surface
Figure 4.8 Measure to Top of Last Section of Pipe
Majestic • JADE32IN-B, JADE42IN-B, JADE42IL-B Installation Manual • 2619-986 Rev. B • 10/19
cap).
MEASURE TO SHADED SURFACE
(OUTSIDE MOUNTING SURFACE)
See
X
For X and Y dimensions, see Figure 4.4.
Figure 4.9 Measure Horizontal and Vertical Termination
Clearance to Trapezoid Portion of Cap
OVERHANG
WALL
Y