The table below lists macros for commissioning. Using the macros "1" or "5" allows a
standard terminal circuit to be achieved. This terminal circuit can be modified according to
the terminal plan.
Table 3-1
Number
1
5
100116
150399
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
Macros for commissioning
File name
Description
pm000001.acx
Line Module with DRIVE-CLiQ :
ALM:
SLM with DRIVE-CLiQ:
pm000005.acx
Line Module without DRIVE-CLiQ :
pm100116.acx
The following parameters are set on all 6 drives:
pm150399.acx
Update of all drive components
Interconnection p0840 (infeed)
Interconnection 2. OFF 3 (rapid stop)
Reserving input and output terminals for two SH/SBC groups
Bero 1 – zero mark substitute
1. Probe
4 x Digital NC – Input ($A_IN[1] ...[4] )
Feedback Line Module
2 x digital NC – output ($A_OUT[1] ...[2] )
Shutdown of network identification (p3410=0)
Network identification of the SLM is performed automatically
on the next pulse enable (p3410=5).
Interconnection p0864 to all drives
Interconnection 2. OFF 3 (rapid stop)
Reserving input and output terminals for two SH/SBC groups
Bero 1 – zero mark substitute
1. Probe
4 x Digital NCK – Input ($A_IN[1] ...[4] )
4 x digital NCK – output ($A_OUT[1] ...[4] )
Set up two encoder data sets p140=2
Eight drive data sets p180=8
Profibus protocol p922 = 116
NCU/NX Terminal Assignment
3.3 Macros for commissioning