7.5

Circuit Manual Group =3

7.5
Drive group with line contactor, Smart Line Module without DRIVE-CLiQ connection, without safety
functions, motor protection without Voltage Protection Module (VPM).
● Power supply of the NCU 710 (=3.-K11)
● Control signals to the NCU; digital inputs and digital outputs in accordance with standard
● DRIVE-CLiQ connection to the Motor Module
● PROFIBUS connection to the distributed peripherals
● Supply and control of the Smart Line Module (=3.-Q51), including the integration of the
● Supply and control of the Single Motor Module
● Connection of the motor, holding brake and sensor system to the Motor Module (=3.-Q61)
● Connection of the motor and separate sensor system (=3.-B78) to the Motor Module (=3.-
● Motor protection (=3.-F75) by the Voltage Protection Module (VPM)
The drive group consists of the Control Unit (=3.-K11), the Smart Line Module (=3.-Q51), two
Motor Modules (=3.-Q61, =3.-Q71), the Voltage Protection Module (=3.-F75) and the SIMAG
H2 (=3.B78) actual value sensor. The DRIVE-CLiQ connection is used for the
communication between the Control Unit and the Motor Modules.
Functions
● Signal exchange
● Interlocking of external status and fault signals
● Interlocking of component states and system signals
● Enable signal from the Smart Line Module (5/10 kW)
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
macro specifications
auxiliary contact of the main power switch
Q71)
The signal exchange between the NCU 710 Control Unit and the PLC
External fault signals, such as the monitoring of the safety cut-outs (=1.-F62, =1.-F63,
=1.-F64), circuit-breakers (=1.-Q36, =1.-Q41), etc., may also need to be interlocked with
the On/Off command. Signals can be visualized appropriately on the Operator Panel.
Depending on their information and importance, some internal status signals can or must
be linked with the On/Off command, controller enable, etc.
The protective circuit of the Enable Pulses digital input (X21: 3/ 4) is required for the
Smart Line Module (=3.-Q51). Before the main power switch is used to switch off the
drive group, the Enable Pulses input on the Smart Line Module must be disabled, for
example, using a leading (<=10 ms) auxiliary switch on the main power switch. The
"Infeed Ready" signal is activated only when the Smart Line Module is operating correctly
and the DC link has started properly.
Typical circuit diagrams
7.5 Circuit Manual Group =3
7-21