Siemens SINUMERIK 840D sl Manual page 255

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Off responses
● OFF1
● OFF2
● OFF3
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
– The immediate specification of n_set = 0 at the ramp generator return ramp (p1121)
causes the drive to be braked.
– When zero speed is detected, the motor holding brake (if parameterized) is closed
(p1215). The pulses are suppressed when the brake application time (p1217) expires.
The standstill is detected when the actual speed value of the speed threshold (p1226)
is undershot or when the monitoring time (p1227) started when speed setpoint ≤
speed threshold (p1226) has expired.
– Immediate pulse suppression, the drive coasts to standstill.
– The motor holding brake (if parameterized) is closed immediately.
– Power-on inhibit is activated.
– The immediate specification of n_set = 0 at the OFF3 return ramp (p1135) causes the
drive to be braked.
– When zero speed is detected, the motor holding brake (if parameterized) is closed.
The pulses are suppressed when the application time of the holding brake (p1217)
expires. The standstill is detected when the speed actual value of the speed threshold
(p1226) is undershot or when the monitoring time (p1227) started when speed
setpoint ≤ speed threshold (p1226) has expired.
– Power-on inhibit is activated.
Activate/Deactivate Drive System
9.2 Drive Group with Several Axes
9-5