Thermon Terminator ZP-M Installation Procedures Manual

Power connection kit for power connection, in-line splice connection, or end termination applications

Advertisement

Quick Links

Terminator
Power Connection Kit for Power
Connection, In-Line Splice Connection,
or End Termination Applications
INSTALLATION PROCEDURES
ZP-M
TM
Listed Heat Tracing Cable System 137M
Ordinary & Hazardous Locations
Class I, Division 2, Groups A, B, C & D
Class II, Division 2, Groups F & G, Class III
Class I, Zone 1, AEx e II T4-T6; Ex e II T4-T6
0539
II 2 G & D Ex e II T4-T6
IEC Ex UL 05.0003 Ex e II T4-T6

Advertisement

loading
Need help?

Need help?

Do you have a question about the Terminator ZP-M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermon Terminator ZP-M

  • Page 1 Terminator ZP-M Power Connection Kit for Power Connection, In-Line Splice Connection, or End Termination Applications INSTALLATION PROCEDURES Listed Heat Tracing Cable System 137M Ordinary & Hazardous Locations Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G, Class III Class I, Zone 1, AEx e II T4-T6;...
  • Page 2: Kit Contents

    Terminator ZP-M Dimensions The following installation procedures are suggested guidelines for the installation of the Terminator ZP-M Kit. For translations other than English and local language translation provided here, please contact Thermon. The English language installation procedure shall govern. Receiving, Storing and Handling 1.
  • Page 3: Installation Procedures

    INSTALLATION PROCEDURES Cable Type Cable Type Cable Type HTEK 3C60 HTEK 3C40 HTEK 2C50 HTEK 3C50 HTEK 3C30 HTEK 2C40 TEK 3C70 HTEK 2C70 HTEK 2C30 HTEK 2C60 TEK 3C40 TEK 3C60 TEK 3C30 TEK 3C50 TEK 2C60 TEK 2C70 TEK 2C50 TEK 2C40 TEK 2C30...
  • Page 4 Terminator ZP-M Separate braid strands at edge of overjacket and Cut and remove pairing jacket by scoring pairing Remove insulation and fiberglass braid (HTEK pull cable through opening in braid. Twist braid jacket and bending cable. Do not cut insulation only) from ends of each conductor.
  • Page 5 INSTALLATION PROCEDURES Install junction box lid and twist hand tight. Use screwdriver to ratchet on junction box lid. Lid latch mechanism fully engaged. To remove Insert screwdriver into ratchet slots located on Lid will rotate 30 degrees. lid, repeat steps 20 and 21 but in the opposite side of junction box base.
  • Page 6 NOTE: Images may not be printed to scale. Thermon • 100 Thermon Dr • PO Box 609 San Marcos, TX 78667-0609 • Phone: 512-396-5801 • 1-800-820-4328 For the Thermon office nearest you visit us at . . . www.thermon.com Form No. PN50828-0519...