Advertisement

NiCrSi-NiSi N
EN 60584
Pt10Rh-Pt S
EN 60584
Pt13Rh-Pt R
EN 60584
Pt13Rh-Pt6Rh B EN 60584
W3Re-W25Re D
Cold junction
Cold junction accuracy
Sampling
Input filter
Features
1. Accuracy refers to the maximum extent of the measuring range.
DC voltage, DC current
Measuring range
0 to 20mA, voltage drop < 2 V
4 to 20mA, voltage drop < 2 V
0 to 10V, input resistance > 100 kΩ
2 to 10V, input resistance > 100 kΩ
Scaling
Sampling time
Input filter
2011-12-31
-100 to +1300°C
0 to +1768°C
0 to +1768°C
300 to 1820°C
0 to +2495°C
Pt 100, internal
± 1K
210 ms
2nd order digital filter; filter constant adjustable from 0 to 100secs
also programmable in °F
Accuracy
0.2%
0.1%
freely programmable within the limits
210 ms
2nd order digital filter; filter constant adjustable from 0 to 100secs
0.4%
0.4%
0.4%
0.4%
0.4%
8 Technical data