4000 Series
Art. 4903
Codelock Module for the GSMPRO

TERMINAL CONNECTIONS

Connection
Description
+
12-24V AC or DC power input
-
0V power input
C1
Relay 1 common connection
NO1
Relay 1 normally open connection
NC1
Relay 1 normally closed connection
C2
Relay 2 common connection
NO2
Relay 2 normally open connection
NC2
Relay 2 normally closed connection
SW1
Switched 0V input to trigger relay 1
SW2
Switched 0V input to trigger relay 2
A
RS485 bus terminal connections
B
IT IS RECOMMENDED THAT ANY CABLING AND VIDEX PRODUCTS BE INSTALLED BY A COMPETENT AND
QUALIFIED ELECTRICIAN, SECURITY INSTALLATION SPECIALIST OR COMMUNICATIONS ENGINEER.
WIRING DIAGRAM (AS STANDALONE KEYPAD)
NOTES:
The HDR-15-12 power supply requires 230Vac (50/60Hz) mains input.
lock circuit. Next move the lock wire from NC1 across to the NO1 terminal. Also set the MOV jumper to the NO1 position.
For connections to gate controls wire into terminals C1 / NO1 if using relay 1 and terminals C2 / NO2 if using relay 2. Also
remove the respective MOV jumper.
12Vdc
Emergency Break Glass
MAG LOCK
14-20V
MOV
For RS485 network connection, cabling information and installation notes refer to the wiring diagram on page 7.
Art. 4903 - Installation Instructions
EMERGENCY
DOOR RELEASE
4903
STEEL
ALI
HIGH BRASS
MATTE
ON
RS485 BUS TERMINATION

TECHNICAL SPECIFICATION

Working voltage:
Current consumption:
Number of relays:
Relay current/voltage:
Push to exit inputs:
RS485 bus connections:
RS485 termination:
Back light adjustment:
Networkable:
Back EMF protection:
Number of codes:
Programming:
Working Temperature:
MOV jumper set
to NC1 position
for fail safe lock
OFF
- 6 -
ENG
12V - 24Vac/dc +/- 10%
20mA (standby), 70mA (max.)
2, RLY1 and RLY2 (C, NC and NO)
3A @ 24Vac/dc (max.)
2, SW1 and SW2 (switched 0V)
Yes, A and B
Jumper JP1
Jumper JPL
Yes via RS485 (8 devices max.)
2x MOV jumpers, JP2 and JP3
2 codes, 1 per relay (standalone);
400 permanent codes (via RS485);
32 temporary codes (via RS485)
Via keypad (standalone);
SMS text message (via RS485);
GSMSK PC software (via RS485)
-10 +50
C
o
66251800 - V1.2 - 09/04/19