28
www.aeg.com
13.6 Gas Connection
Use a flexible pipe in compliance with
the regulation in force. Make sure they
do not come in touch with mobile parts
and are not squeezed.
WARNING!
Only a qualified and
competent person can do
the gas installation.
Before you connect te gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the fuse
box. Close the primary valve
of the gas supply.
Supply piping should not be
less than R3/8. Connection is
made to the Rc 1/2 (1/2
" B.S.P.) female threaded.
The entry pipe is located just
below the hob level on the
rear left hand side of the
appliance.
The gas supply ramp is on
the rear side of the
appliance.
WARNING!
Only liquid sealants can be
used when the inlet gas pipe
is fitted i.e.: do not use the
P.T.F.E. sealant tape.
When the installation is
complete, carry out a gas
tightness test and make sure
that the seal of each pipe
fitting does not leak.
Use flexible tubing, which
comply with the BS.669
current edition.
A
B
C
WARNING!
The gas bayonet connector
must be in the marked area.
Dimension
A
B
C
D
E
13.7 Pressure test
The Rapid injector is used as a pressure
test point.
1. Connect the pressure gauge to the
Rapid injector.
2. Examine the supply pressure by
turning the Rapid burner and one
other burner fully on, and lighting
them. The pressure must be 20 mbar
for Natural Gas.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work
correctly.
13.8 Checking the hob burners
1. Lift the lid.
2. Put on the burner crowns and caps.
Make sure that they are correctly
seated.
3. Put on the pan supports.
E
D
C
mm
250
680
50
250
580

Hide quick links: