If the burner accidentally
goes out, turn the knob to
the off position and try to
light the burner again after
minimum 1 minute.
5.2 Burner overview
G
F
5.3 Replacing burner parts
1. Put carefully the burner crown on the
burner body. Let the crown fall freely
onto the body. Do not use force.
Make sure that the hole in the crown
is above the ignition candle.
Make sure that the location pegs are
in the slots in the burner body.
Make sure that you can move the
crown a small distance from side to
side.
2. Put the burner cap centrally on top of
the crown.
Make sure that the cap is correctly
installed, with the enamel side up
and you can move the cap from side
to side and front to back.
3. Light the burner.
If the burner does not ignite, adjust the
crown and cap again.
5.4 Turning the burner off
To put the flame out, turn the knob to
the off position
.
The spark generator can
start automatically when you
switch on the mains, after
installation or a power cut. It
is normal.
A. Burner cap
A
B. Burner crown
C. Slots
D. Thermocouple
E. Ignition candle
F. Burner body
B
G. Hole for the ignition candle
C
D
E
WARNING!
Always turn the flame down
or switch it off before you
remove the pans from the
burner.
5.5 Lid Safety Device
Lid has safety device, which cuts off the
gas supply for the hob. Closing the lid
activates the safety device.
WARNING!
Always use the knob for the
hob to switch off a burner.
Do not use the lid as a cut-
off device.
ENGLISH